ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
This is related to previous 806 Notifications about uncommanded movements of a motorized mobile x-ray system. Reason for Recall: Along with the previously noted encoder and gauges problems and corresponding fixes, we have observed that static electricity can also elicit the unwanted behavior.
UltraFlex IAB: 7.5Fr 40cc; Product Code: IAB-06840-U The Arrow¿ IAB is utilized for intra aortic balloon counterpulsation therapy in the aorta, whereby balloon inflation, during diastole and deflation, during systole increases blood supply to the heart muscle and decreases work of the left ventricle.
Arrow International, Inc., Division of Teleflex Medical
The sheath body may become separated from the sheath hub. If the separation occurs, there is a potential for bleeding from the device.
Percutaneous Insertion Tray; Product Code: IAK-S7IT The Arrow¿ IAB is utilized for intra aortic balloon counterpulsation therapy in the aorta, whereby balloon inflation, during diastole and deflation, during systole increases blood supply to the heart muscle and decreases work of the left ventricle.
Arrow International, Inc., Division of Teleflex Medical
The sheath body may become separated from the sheath hub. If the separation occurs, there is a potential for bleeding from the device.
The firm has become aware of the potential for disruption (flickering) in the video laryngoscopy image when GlideScope Titanium SU laryngoscope blades are in use. Video "flickering" appears as the intermittent break-up of the on-screen video image, appearing as either distorted horizontal or vertical bars of displaced video signal.
Iris International noted loose or missing analyte pads found in several locations (strip vial, strip provider module, strip conveyor system or waste container) that are undetectable by the iChemVELOCITY System.
ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay
The firm has received one report of values for patient height and weight being switched when input at the Xhibit Central Station, Model 96102, causing a bedside monitor Body Surface Area (BSA) calculation to be in error.
ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay
Zimmer Biomet Inc. Verso Shoulder Forked Retractor (Comprehensive Instrumentation 2 Prong Retractor) supplied by Kirkstall Precision was made according to the W1.4034 (420 stainless) which does not conform to 420 S29 indicated on the print. All units manufactured to date were manufactured using 420 stainless. Therefore, all lots of PN: 402852 are considered in scope.
Potential for power cord to melt; hazards include electric shock and fire.
Screws holding the detector panel in as a result the detector panel could make contact with other parts with in the 0-arm¿ 02 Imaging System, causing noise and vibration when being positioned or during 3D Imaging could lead to poor image quality
The sterility of the product cannot be assured. This may result in increased risk of infection.
Arrow has issued a recall for these products due to potential packaging damage. The sterility of the products cannot be guaranteed. If non-sterile product is used there is a potential for infection to occur.
Customer complaints about failed target ranges for alpha angle. Firm has not completed the CAPA identifying the root cause. Projected completion of the CAPA by the firm is July 2016.
FiberOptix Ultra 8 IAB: 8Fr 40cc; Product Code: IAB-05840-LWS The Arrow¿ IAB is utilized for intra aortic balloon counterpulsation therapy in the aorta, whereby balloon inflation, during diastole and deflation, during systole increases blood supply to the heart muscle and decreases work of the left ventricle.
Arrow International, Inc., Division of Teleflex Medical
The sheath body may become separated from the sheath hub. If the separation occurs, there is a potential for bleeding from the device.
(Stryker) AccuPlace Round Level Needle Guide; Assists the user with inserting a needle at a predetermined angle for computer tomography.
Stryker Instruments Div. of Stryker
During an evaluation of the product packaging, it was determined that there is a potential for the product to cause damage to the packaging, creating a possible breach in sterility.
PICC/CVC Secure Dressing Change kit, Ref: 73775, Lot 213403, Sterile Single Use, Medical Action Industries, Inc., Arden, NC. This kit is used by clinicians to change dressings
Medical Action Industries
Misbranding; Due to the presence of CHG in the Tegaderm PICC/CVC dressing change convenience kit, which is not identified on the exterior labeling
Potential for higher than specified surface temperatures. Use of 3.0T GEM Flex system may result in patient warming or burns.
Aesculap Inc. US has initiated a recall on Tibial and Femur extension sterile pressfit stem implant packaging that are used for Columbus Revision/Enduro Knee Implants because it is labeled as Cementless. US product is indicated in the US for use with Bone Cement only.