Medical Devices Recalls

Medical equipment, implants, and diagnostic devices

38,779 Total Recalls

CareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface Module (UIM).

May 17, 2016 Patient Monitors Nationwide View Details →

CareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface Module (UIM).

May 17, 2016 Patient Monitors Nationwide View Details →

As a result of an internal investigation of a non-conformance it has been determined: 1) Depth Gauges from Lot UP15H2 exceed the overall length specification requirements. 2) Depth Gauges from prior lot numbers manufactured before Integra acquired the product line reflect an incorrect number for the first mm depth marking on the gauge. The number should be 4, it is 6. 3) The space / holder

May 10, 2016 Implants & Prosthetics View Details →

00720504022 ACETAB.CUPW/SH,0DEG,22MMX40MM 00720504222 ACETAB.CUPW/SH,0DEG,22MMX42MM 00720504622 ACETAB.CUPW/SH,0DEG,22MMX46MM 00720504828 ACETAB.CUPW/SH,0DEG,28MMX48MM 00720505228 ACETAB.CUPW/SH,0DEG,28MMX52MM 00720505628 ACETAB.CUPW/SH,0DEG,28MMX56MM 00720505828 ACETAB.CUPW/SH,0DEG,28MMX58MM 00720506028 ACETAB.CUPW/SH,0DEG,28MMX60MM 00720506228 ACETAB.CUPW/SH,0DEG,28MMX62MM 00720506428 ACETAB.CUPW/SH,0DEG,28MMX64MM 00721004222 ACETAB.CUPW/SH,10DEG,22MMX42MM 00721004422 ACETAB.CUPW/SH,10DEG,22MMX44MM 00721005028 ACETAB.CUPW/SH,10DEG,28MMX50MM 00721005228 ACETAB.CUPW/SH,10DEG,28MMX52MM 00721005628 ACETAB.CUPW/SH,10DEG,28MMX56MM 00721006428 ACETAB.CUPW/SH,10DEG,28MMX64MM 00721006628 ACETAB.CUPW/SH,10DEG,28MMX66MM 00721006828 ACETAB.CUPW/SH,10DEG,28MMX68MM 00721007028 ACETAB.CUPW/SH,10DEG,28MMX70MM 00725504222 ACETAB.CUP, 0 DEG, 22MM X 42MM 00725504622 ACETAB.CUP, 0 DEG, 22MM X 46MM 00725504626 ACETAB.CUP, 0 DEG, 26MM X 46MM 00725504828 ACETAB.CUP, 0 DEG, 28MM X 48MM 00725505232 ACETAB.CUP, 0 DEG, 32MM X 52MM 00725505432 ACET CUP, 0 DEG, 32MM X 54MM 00725505632 ACET CUP, 0 DEG, 32MM X 56MM 00725505828 ACETAB.CUP, 0 DEG, 28MM X 58MM 00725505832 ACET CUP, 0 DEG, 32MM X 58MM 00725506028 ACETAB.CUP, 0 DEG, 28MM X 60MM 00725506032 ACET CUP, 0 DEG, 32MM X 60MM 00725506228 ACETAB.CUP, 0 DEG, 28MM X 62MM 00725506232 ACET CUP, 0 DEG, 32MM X 62MM 00725506428 ACETAB.CUP, 0 DEG, 28MM X 64MM 00725506432 ACET CUP, 0 DEG, 32MM X 64MM 00725506628 ACETAB.CUP, 0 DEG, 28MM X 66MM 00725506632 ACET CUP, 0 DEG, 32MM X 66MM 00725506828 ACETAB.CUP, 0 DEG, 28MM X 68MM 00725506832 ACET CUP, 0 DEG, 32MM X 68MM 00725507028 ACETAB.CUP, 0 DEG, 28MM X 70MM 00725507032 ACET CUP, 0 DEG, 32MM X 70MM 00726004222 ACETAB.CUP,10 DEG, 22MM X 42MM 00726004828 ACETAB.CUP,10 DEG, 28MM X 48MM 00726005028 ACETAB.CUP,10 DEG, 28MM X 50MM 00726005228 ACETAB.CUP,10 DEG, 28MM X 52MM 00726005232 ACETAB.CUP,10 DEG, 32MM X 52MM 00726005432 ACET CUP, 10 DEG, 32MM X 54MM 00726005632 ACET CUP, 10 DEG, 32MM X 56MM 00726005832 ACET CUP, 10 DEG, 32MM X 58MM 00726006032 ACET CUP, 10 DEG, 32MM X 60MM 00726006428 ACETAB.CUP,10 DEG, 28MM X 64MM 00726006432 ACET CUP, 10 DEG, 32MM X 64MM 00726006628 ACETAB.CUP,10 DEG, 28MM X 66MM 00726006632 ACET CUP, 10 DEG, 32MM X 66MM 00726006828 ACETAB.CUP,10 DEG, 28MM X 68MM 00726006832 ACET CUP, 10 DEG, 32MM X 68MM 00726007028 ACETAB.CUP,10 DEG, 28MM X 70MM 00726007032 ACET CUP, 10 DEG, 32MM X 70MM

Zimmer Trabecular Metal Technology

Class I - Dangerous

Zimmer Biomet is initiating a recall of specific lots of foil pouched, sterile Trabecular Metal implants that were manufactured between April 2011 and October 2012. The foil pouches are part of a dual barrier system to provide sterile integrity.

Apr 15, 2016 Other Medical Devices Nationwide View Details →

Zimmer Biomet is initiating a recall of specific lots of foil pouched, sterile Trabecular Metal implants that were manufactured between April 2011 and October 2012. The foil pouches are part of a dual barrier system to provide sterile integrity.

Apr 15, 2016 Other Medical Devices Nationwide View Details →

PICC catheters that contain valve(s) manufactured prior to July 15, 2014 lack a manufacturing specification change that reduces the incidence of hemolysis during blood sampling through the PICC catheter.

Mar 14, 2016 Infusion Pumps Nationwide View Details →

PICC catheters that contain valve(s) manufactured prior to July 15, 2014 lack a manufacturing specification change that reduces the incidence of hemolysis during blood sampling through the PICC catheter.

Mar 14, 2016 Diagnostic Equipment Nationwide View Details →

CareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface Module (UIM).

May 17, 2016 Patient Monitors Nationwide View Details →

Product incorrectly packaged. The labels on the outside of the box and on the LCP Dia-Meta Volar Distal Radius Plate inside the box are correct; however, the preprinted box which contains the LCP-Dia-Meta Volar Distal Radius Plate is incorrect. The box is preprinted for a 4.5 mm LCP Condylar Plate - Distal Femur.

May 2, 2016 Other Medical Devices View Details →

It was discovered during post-quarantine packaging on 2/16/2016 that the IFU for the STATLOCK Sheath Stabilization device for Percutaneous Sheath Introducer (Vendor PN 2403097-1405R) was erroneously packaged with the Mega and Sensation Plus IAB Catheter Kits instead of the IFU for the STATLOCK Catheter Stabilization device for IAB catheters (Vendor PN 24030905-1406R).

May 13, 2016 Surgical Instruments View Details →

Ortho Clinical Diagnostics confirmed a software timing anomaly in which the VITROS 3600 and 5600 Systems may unexpectedly aspirate from or dispense into an unintended sample that may lead to erroneous or contaminated results.

Apr 6, 2016 Infusion Pumps Nationwide View Details →

The 4 ml FX Sodium Fluoride/Potassium Oxalate tube may have no or low additive (sodium fluoride and potassium oxalate), which can effect analytical results for glucose and lactate.

Apr 26, 2016 Other Medical Devices Nationwide View Details →

Beckman Coulter has identified that Dipyrone (Metamizole) may cause erroneous, false low results in the following assays: Cholesterol OSR6X16, Triglyceride OSR6X118, Uric Acid OSR6X98, Lactate OSR6X93, and Lipase OSR6X30.

Apr 13, 2016 Infusion Pumps Nationwide View Details →

Software Defects resulting in: (1) sagittal result shortened for axial scans; (2) single series displayed on console viewer when Creating multi-planner reconstruction; (3) scan length changes with a change in field of view; (4) DoseRight algorithm miscalculations leading to incorrect CTDI values; (5) scan length changes during subsequent axial results, (6) surview scan lengths near 135mm or 184mm

Sep 6, 2015 Other Medical Devices Nationwide View Details →