The rods are packaged in packages with unacceptable seals. In some cases, the integrity of the seal is compromised by channels or voids.
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
Stryker Instruments is voluntarily recalling specific lots of sterile MIS Toolsteel Burs because the burs may exhibit signs of corrosion.
Defective tips have the potential to pipette/dispense volumes 50-100% lower than is specified for the tips.
A limited number of product pouches may not have been sealed during packaging.
Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use.
AbbVie PEG Kit 20 FR
AbbVie
AbbVie is issuing an urgent field correction notification due to an increased number of reports of disconnections of the AbbVie 20FR PEG tube from the Y-connectors.
Greatbatch Medical the manufacturer of the 4F and 5F sheath/dilator components has determined that the products listed in their September 7, 2016 Recall Notification have the potential for the rotating luer to detach from the dilator hub during use. AngioDynamics has confirmed that affected sheath/dilators (Greatbatch Model Numbers 10904-001 and 10904-002) have been included in packaged AngioDynamics Stiffened Micro-Introducer Kits.
Product sterility is compromised due to breach of the sterile barrier
Product Defect; These products may produce a straight stream instead of a fully atomized plume of medication.
Synthes VA Implant Rack for the Compact Distal Radius System Tray/Surgical/Instrument
Synthes (USA) Products
The screw rack plate was assembled incorrectly which could cause the screws in the screw rack to sit low and touch the surface beneath the screw rack.
A limited number of product pouches may not have been sealed during packaging.
Owens & Minor is the initial importer and private label distributor of Medi Choice Arm Slings (Product). The Product is manufactured in China by Tops Medical Articles Nantong Inc. Owens & Minor first learned of the product issue that prompted the product removal action via customer complaints received in September 2016. Two customer complaints received on September 1"1, 2016 reported surface contamination on the arm slings. Two additional complaints reported on September 19, 2016 and October 7, 2016 reported the same issue. Upon receipt of the complaints on September 1, 2016, Owens & Minor immediately initiated a CAPA investigation for root cause analysis and determination of corrective/preventive actions. A quality inspection of inventory confirmed that the surface contamination was confined to lots manufactured in May, June, and July of 2016. The surface contamination for these lots was found to be frequent. Subsequent August product lots were inspected and no surface contamination was found. Limited inventory from lots prior to May 2016 were available and inspected as well. No surface contamination was found on these prior lots. Owens & Minor has quarantined the affected product lots. The product is on hold at all Owens & Minor Distribution Centers (DC). Samples of contaminated product have been sent to the manufacturer for evaluation and to a certified testing lab for identification of contaminate. These results are pending at this time. Based on the frequency of the product defect as well as evaluation of potential adverse health event risk, Owens & Minor initiated a voluntary recall for the above stated affected product lots.
A limited number of product pouches may not have been sealed during packaging.
Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use.
Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use.
RUSCH, Pocket PAC IC Intermittent Cath Kit, 8 FR, 12 FR, 14 FR, 10 FR and 16 FR, Rx Only, Sterile, Intermittent self-catheterization
Teleflex Medical
Labeling Inconsistency: The products have been labeled with the incorrect expiration date which exceeds the actual, validated 35-month shelf life.
DELFIA hFSH kit. In Vitro Diagnostic for the determination of hFSH in serum
PerkinElmer Health Sciences
A DELFIA hFSH kit lot failed real time stability testing. The real time stability data demonstrated a decrease in hFSH concentrations between -4.8% to -11.3% for control sera. The -11.3% bias was observed at an hFSH target concentration of 101 IU/L. The change observed in the serum samples within the range 1.76 67.0 IU/L hFSH averaged -2.9%. The reference range of the assay spans 0.60 to 98.0 IU/L.
Ultroid Sterile Disposable Probes sold individually
Ultroid Technologies
Products are not designed, qualified, manufactured, and/or managed under a state of control per internal quality system procedures and external laws, regulations, directives, standards, and/or guidance (such as 21 CFR 820 Quality System Regulation)
Complaint that during insertion of the dilator through the sheath a fragment of inner liner came out of the sheath prior to use.
Siemens Healthcare Diagnostics has confirmed that the IMMULITE/ IMMULITE 1000 Systems PSA assays are not meeting the current High-dose Hook Effect expectation in the Instructions for Use.