Medical Devices Recalls

Medical equipment, implants, and diagnostic devices

38,779 Total Recalls

Smiths Medical has become aware that the drawing on the Instructions for Use (IFU) on certain yellow striped CADDΒΏ Administration Sets (part number 21-7339-24), incorrectly represent the actual filter size of the product. Although the text description on the IFU correctly identifies the product to include a 0.2 micron filter, the illustration on the IFU identifies the filter size as 2.0 microns.

Mar 17, 2017 Other Medical Devices Nationwide View Details β†’

For over a year, the Accessory Packages in the Hyfrecator 2000 ESU cartons were packaged in error by the manufacturer with non-sterile P/N 7-796-19 Handpiece Sheaths in pouches that were labeled as Sterile. This could cause an end user to use a non-sterile sheath as if it were Sterile.

Feb 28, 2017 Surgical Instruments Nationwide View Details β†’

Intuitive Surgical has become aware that in specific scenarios with system software P6 and the da Vinci Xi Suction Irrigator (PN 480299-03), users can experience unexpected motion of a system arm.

Mar 31, 2017 Surgical Instruments View Details β†’

A complaint was received on January 1, 2017 stating the pigtail on line 2 of the oxygenator was assembled to the port where the yellow cap and the clear cap remained on the center port.

Feb 16, 2017 Other Medical Devices View Details β†’

Increased frequency of calibration failures for VITROS Immunodiagnostic Products NT-proBNP Reagent Lots 1568, 1570, 1580 and 1590, due to background signals for these affected NT-proBNP lots that have been increasing with time since release testing, resulting in higher than expected VITROS Immunodiagnostic Products NT-proBNP level 1 calibrator signals produced, leading to calibration failures.

Mar 7, 2017 Diagnostic Equipment View Details β†’

Aesculap Implant Systems LLC is recalling the Minop Trocar due to the possibility it may have sharp edges on the distal end which may lead to the abrasion of the insulation when removing the electrode.

Mar 7, 2017 Other Medical Devices View Details β†’

For over a year, the Accessory Packages in the Hyfrecator 2000 ESU cartons were packaged in error by the manufacturer with non-sterile P/N 7-796-19 Handpiece Sheaths in pouches that were labeled as Sterile. This could cause an end user to use a non-sterile sheath as if it were sterile.

Feb 28, 2017 Surgical Instruments Nationwide View Details β†’

Unapproved change made by the supplier.

Feb 27, 2017 Diagnostic Equipment Nationwide View Details β†’