The connector of the power supply was capable of fitting other components provided with the system. However, the voltage output of the reader power supply is incompatible with the other component and, if incorrectly connected, could result in irreparable damage to the system.

Apr 2, 2018 Diagnostic Equipment Nationwide View Details β†’

Possible failure of screws which hold the gas spring fixation bracket in place. Due to this failure, the gas spring, which is fixed to the upper part of the parallelogram, cannot hold up the weight of the optics carrier.

Jun 4, 2018 Surgical Instruments Nationwide View Details β†’

This voluntary recall is being conducted due to the curved tip introducer needle which is included in the kit, to have a potential manufacturing defect. This could result in difficulty advancing or withdrawing the Vectris lead through the curved tip introducer needle.

May 25, 2018 Implants & Prosthetics View Details β†’

The block used to connect the patient pallet to the couch may be assembled incorrectly. A screw may be misaligned in the patient pallet.

May 21, 2018 Diagnostic Equipment Nationwide View Details β†’

The stainless steel belt which runs the length of the table underneath the tabletop is exposed when the tabletop is extended into the magnet for scanning. The firm has received two complaints where technologists have cut their fingers on this belt.

Jun 18, 2018 Diagnostic Equipment Nationwide View Details β†’

Medtronic has become aware that certain lots of the VCLAS 3MM, 10MM, and 15MM laser diffusing fibers were not tested at intended laser power levels, due to an issue related to calibration of the test equipment, which can lead to the potential for low laser energy output from fiber or fiber burnout at lower wattage.

Mar 23, 2018 Diagnostic Equipment Nationwide View Details β†’

Certain VOLISTA StandOP Surgical Lights have been identified as having a potential light head detachment issue. Improper assembly of the bracket that connects the light head to the axle fork could result in the light head bracket breaking, causing the light head to detach from the arm and become suspended only from the cabling inside the arm. Use of an affected device may result in serious injury to patient and/or medical staff if the light head detaches and drops, impacting patient and/or medical staff during demonstration, service, or use.

Jun 14, 2018 Diagnostic Equipment Nationwide View Details β†’