In rare cases of insufficient maintenance or high clinical workload, the first rope of the ceiling stand, which is designed to take the load, could break without triggering the safety lock and this could lead to overloading the safety rope which is not designed for continuous load and ongoing movement under load. This may lead to mechanical fatigue and cause the arm to drop down during patient positioning. Patients and users may be seriously injured.
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to Service Engineers working inside the gantry.
Handicare C Series Patient Lift Product Usage: A device used to lift and transport a patient from one place to another.
Handicare Usa
Premature strap wear and breakage at maximum weight conditions (625 lbs.).
DigitalDiagnost 4 Chest / Emergency (Stitching Patient Support) 712029
Philips Medical Systems Gmbh, DMC
The hook does not securely hold the footplate in the vertical position. Therefore, the footplate can fall or swing down and injury operator or patient.
O-Two EquinoxΒΏ Relieve N2O/O2 Analgesic Gas Mixing and Delivery System Model#: 01EQ1000
O-Two Medical Technologies
Higher levels of nitrous oxide delivered than specification
Philips has received several reports in which monitors with lithium ion batteries that had exceeded their battery life expectancy have overheated or ignited. These batteries should be replaced every 3 years or upon reaching 300 charge-discharge cycles. Although the Philips SureSigns VS & VM Monitors and View Station (VSV) can display actual information on either or both battery age and charge-discharge cycles, the existing labeling does not include full instructions on how to use this information to determine when to replace the battery. An overheated battery may in turn cause the device case to overheat and possibly melt or cause the device to ignite, which can cause injury to a patient, nearby users, or cause damage to property.
EasyDiagnost Eleva DRF, Release 5 (Stitching Patient Support) 706050
Philips Medical Systems Gmbh, DMC
The hook does not securely hold the footplate in the vertical position. Therefore, the footplate can fall or swing down and injury operator or patient.
Ortho Kinematics, Inc. notified customers of erroneous results of VMA tests due to a software bug that has been corrected.
Software issue. The difference between the display and dosimeter readings In the Child/Pediatric automatic exposure mode is in the range of 52-65%. The display in all other modes deviated by less than 35% from the dosimeter readings.
DigitalDiagnost 4.1 (Stitching Patient Support) 712225
Philips Medical Systems Gmbh, DMC
The hook does not securely hold the footplate in the vertical position. Therefore, the footplate can fall or swing down and injury operator or patient.
DigitalDiagnost Classic 1.x Upgrades (Stitching Patient Support) 712081
Philips Medical Systems Gmbh, DMC
The hook does not securely hold the footplate in the vertical position. Therefore, the footplate can fall or swing down and injury operator or patient.
Order Status Remains Approved When Should Indicate Complete.
CoLink(TM) Lapidus Plate +2mm Right and Left, were laser marked incorrectly. In these lots, right plates were laser marked as left plates and the left plates were laser marked as right plates.
CombiDiagnost R90 (Stitching Patient Support) 709030
Philips Medical Systems Gmbh, DMC
The hook does not securely hold the footplate in the vertical position. Therefore, the footplate can fall or swing down and injury operator or patient.
Handicare P600 Series Patient Lift Product Usage: A device used to lift and transport a patient from one place to another.
Handicare Usa
Premature strap wear and breakage at maximum weight conditions (625 lbs.).
DigitalDiagnost Classic, Dual-Detector (Stitching Patient Support) 712052
Philips Medical Systems Gmbh, DMC
The hook does not securely hold the footplate in the vertical position. Therefore, the footplate can fall or swing down and injury operator or patient.
Philips has received several reports in which monitors with lithium ion batteries that had exceeded their battery life expectancy have overheated or ignited. These batteries should be replaced every 3 years or upon reaching 300 charge-discharge cycles. Although the Philips SureSigns VS & VM Monitors and View Station (VSV) can display actual information on either or both battery age and charge-discharge cycles, the existing labeling does not include full instructions on how to use this information to determine when to replace the battery. An overheated battery may in turn cause the device case to overheat and possibly melt or cause the device to ignite, which can cause injury to a patient, nearby users, or cause damage to property.
Incomplete seal on the Tyvek lid may compromise the sterility of the device
DigitalDiagnost Dual Detector (Stitching Patient Support) 712022
Philips Medical Systems Gmbh, DMC
The hook does not securely hold the footplate in the vertical position. Therefore, the footplate can fall or swing down and injury operator or patient.
CoLink(TM) Lapidus Plate +2mm Right and Left, were laser marked incorrectly. In these lots, right plates were laser marked as left plates and the left plates were laser marked as right plates.