Surgical Instruments

🏥 Medical Devices • 7,015 recalls

Three lots tied by two trainees were released without performing the required pull test. If tied with inadequate strength, the proximal ligature could slip toward the tip of the catheter and block the inflation hole, leading to the risk of the tip breaking off, and potentially becoming lost in the blood vessel.

Sep 30, 2022 Surgical Instruments View Details →

Two electronic diode components (D1 & D4) placed in the reverse orientation on the controller printed circuit board assembly may result in premature wear of the power regulator, leading to the regulators failure which could cause a full power loss. If the regulator failure were to occur during a patient procedure, a procedural delay may result

Oct 17, 2022 Surgical Instruments Nationwide View Details →

Disc Preparation instruments contained in the following products: CI-11050-08102515 Longer IdentiTi PO Trial Tip, 11A X 8P X 10 X 25mm, 15¿ TC11050 00840180510810 CI-11050-09102515 Longer IdentiTi PO Trial Tip, 12A X 9P X 10 X 25mm, 15¿ TC11050 00840180510827 CI-11050-10102515 Longer IdentiTi PO Trial Tip, 13A X 10P X 10 X 25mm, 15¿ TC11050 00840180510834 CI-11050-11102515 Longer IdentiTi PO Trial Tip, 14A X 11P X 10 X 25mm, 15¿ TC11050 00840180510841 CI-11050-12102515 Longer IdentiTi PO Trial Tip, 15A X 12P X 10 X 25mm, 15¿ TC11050 00840180510858 CI-11051-10-07 Longer Rotating Disc Shaver, Parallel, 7mm TC11051 00840180511084 CI-11051-20-13 Longer Rotating Disc Shaver, Parallel, 13mm TC11051 00840180511145 CI-11051-20-15 Longer Rotating Disc Shaver, Parallel, 15mm TC11051 00840180511169 CI-11051-20-09 Longer Rotating Disc Shaver, Parallel, 9mm TC11051 00840180511107 CI-11051-20-08 Longer Rotating Disc Shaver, Parallel, 8mm TC11051 00840180511091 CI-11051-20-11 Longer Rotating Disc Shaver, Parallel, 11mm TC11051 00840180511121 CI-11051-10-06 Longer Rotating Disc Shaver, Parallel, 6mm TC11051 00840180511077 CI-11051-20-10 Longer Rotating Disc Shaver, Parallel, 10mm TC11051 00840180511114 CI-11051-20-14 Longer Rotating Disc Shaver, Parallel, 14mm TC11051 00840180511152 CI-11051-10-05 Longer Rotating Disc Shaver, Parallel, 5mm TC11051 00840180511060 CI-11051-20-12 Longer Rotating Disc Shaver, Parallel, 12mm TC11051 00840180511138 CI-11052-01-022-05 Longer Straight Curette, Size 2 TC11052 00840180511282 CI-11052-02-022-05 Longer Up-Angled Pull Curette, Size 2 TC11052 00840180511299 CI-11052-04-022-05 Longer Right-Angled Pull Curette, Size 2 TC11052 00840180511305 CI-11052-05-022-05 Longer Left-Angled Curette, Size 2 TC11052 00840180511312 CI-11071-021-05 Longer Straight Teardrop Curette, Size 2 TC11071 00840180511275

Alphatec Spine

Class I - Dangerous

Due to manufacturing instruments which included additional features and adequate consideration was not given to the need for a new Regulatory filing.

Sep 14, 2022 Surgical Instruments View Details →

Manufacturing error resulted in potential contamination of Bi-Directional navigation catheter irrigation path with cellulose fibers that can cause 1) Failure of initial flushing inspection, 2) Insufficient irrigation causing catheter tip temperature increase, limiting the ability to deliver ablation, or 3) particles flushed through the catheter irrigation may have thrombogenic/toxic effect.

Sep 7, 2022 Surgical Instruments Nationwide View Details →