May have one or more dimensional features out of tolerance includes: thread pitch diameter depth, thread minor diameter depth, plate thickness and end length out of tolerance that can potentially result in a reduced locking strength of an LCP screw
Other Medical Devices
🏥 Medical Devices • 15,203 recalls
The rivets that secure the elastic headband to the face shield have the potential to be mis-assembled. When this condition occurs, it can result in a headband that can become loose from face shield allowing the face shield to shield on the user.
A low risk of a false positive result being issued with a laboratory developed test (LDT) that utilizes the LPH533-A NUP98 Distal Probe Green.
Bariatric Bed Frame System The Citadel Plus Bariatric Bed Frame System is intended for the acute and post-acute care environments. It is not intended for use in the home care environment.
ARJOHUNTLEIGH POLSKA Sp. z.o.o.
Modular Junction Box (MJB) cables can melt and affect the bed functionality.
Smart Stapes Protheses Piston 0.4mm X 5.25 mm- Partial Ossicular Replacement Catalog Number: 70142168
Olympus Corporation of the Americas
Mislabeled outer carton: packaged with the outer carton label stating the contents were the 70143662 Smart Piston but the inside package contents was the 70142158 Stapes Piston; see image below
The 4.5MM PeriLoc Targeter right hand part was anodized green and was marked as a left-hand part.
The contract manufacturer of the calcaneus plate inadvertently used the incorrect material to manufacture the plates (a titanium alloy rather than pure titanium).
The contract manufacturer of the calcaneus plate inadvertently used the incorrect material to manufacture the plates (a titanium alloy rather than pure titanium).
High rate of galling of one threaded component.
Incorrect manufacturer calibration
STAT KIT Model 550AI Emergency Medical Kit. P/N: 1010830 containing various products to include Narcan Nasal spray, item number 1010300
HF Acquisition Co.
Instead of 2 doses, packaged 1 dose of nasal spray in an emergency kits.
STAT KIT Model 550 Emergency Medical Kit P/N: 1009580 containing various products to include Narcan Nasal spray, item number 1010300
HF Acquisition Co.
Instead of 2 doses, packaged 1 dose of nasal spray in an emergency kits.
Incorrect manufacturer calibration
STAT KIT, Model SM30 ; Emergency Medical Kit P/N: 1008670 containing various products to include Narcan Nasal spray, item number 1010300
HF Acquisition Co.
Instead of 2 doses, packaged 1 dose of nasal spray in an emergency kits.
There are potential issues related to the operational state of the scanner, specifically for transport and inadvertent system shutdowns. There could be a possibility of potential delay in patient treatment if proper use instructions are not followed.
The reported stress crack in the port of the swivel elbow where the flip cap is inserted could result in leakage from the breathing system resulting in the prescribed ventilation not being delivered to the patient. These cracks could possibly leak if they reach a significant size and pose a serious heath risk to patient.
Cannon II Plus Replacement Hub Set - Product Usage: is indicated for use in the replacement of a Cannon II Plus hub connection assembly that has been damaged.
Arrow International
The lidstock states the incorrect expiration date for the product. This issue could result in use of a device that is expired which could potentially lead to an increased risk of infection or other complications. Sterility, biocompatibility, safety, or efficacy of the kits and their components are not assured beyond the correct expiration date.
The contract manufacturer of the calcaneus plate inadvertently used the incorrect material to manufacture the plates (a titanium alloy rather than pure titanium).
NextStep Retrograde Replacement Hub Set - Product Usage: is indicated for use in the replacement of a NextStep Retrograde hub connection assembly that has been damaged.
Arrow International
The lidstock states the incorrect expiration date for the product. This issue could result in use of a device that is expired which could potentially lead to an increased risk of infection or other complications. Sterility, biocompatibility, safety, or efficacy of the kits and their components are not assured beyond the correct expiration date.
The contract manufacturer of the calcaneus plate inadvertently used the incorrect material to manufacture the plates (a titanium alloy rather than pure titanium).