Other Medical Devices

🏥 Medical Devices • 15,809 recalls

The Standard Blade may not securely latch onto the Activator Drive. This may result in the inability to stabilize and position or may result in the loss of stabilization and positioning of heart, release of device component into the patient, and/or a procedural delay and/or conversion.

Jun 28, 2023 Other Medical Devices Nationwide View Details →

The Standard Blade may not securely latch onto the Activator Drive. This may result in the inability to stabilize and position or may result in the loss of stabilization and positioning of heart, release of device component into the patient, and/or a procedural delay and/or conversion.

Jun 28, 2023 Other Medical Devices Nationwide View Details →

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

May 15, 2023 Other Medical Devices Nationwide View Details →

Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ANGIO, Model Number: DYNJ905151A; b. ANGIO/VENO PACK, Model Number: DYNJ58346A; c. ANGIOGRAPHIC PACK, Model Number: DYNJ57442C, DYNJ64081A; d. ANGIOGRAPHY PACK, Model Number: DYNJ65963; e. ANGIOPLASTY PACK-LF, Model Number: DYNJ64655; f. ARTHROGRAM TRAY, Model Number: SPEC0232; g. BASIC CATH/ANGIO, Model Number: DYNJ62591A; h. BASIC PACK, Model Number: DYNJ39752A; i. C.I.C.N. ANGIO PACK, Model Number: DYNJ53064B; j. CATH ANGIO PACK, Model Number: DYNJ64050; k. DBD-KIT NEURO CAROTID SETUP, Model Number: DYKMBNDL148; l. DBS PACK-LF, Model Number: DYNJ0878178I; m. GENERAL ANGIO PACK, Model Number: DYNJ57760A; n. GHIASSI NEURO ANGIO PACK-LF, Model Number: DYNJ57032C; o. IR NEURO PACK, Model Number: DYNJ39198L, DYNJ39198N; p. KIT OR AORTOGRM ANGIOPLAST PHT, Model Number: DYNJ906086A; q. MAIN BASIC NEURO, Model Number: DYNJ908260; r. NEURO ACCESSORY PACK, Model Number: DYNJ66790, DYNJ66790A, DYNJ66790B; s. NEURO CATH PACK, Model Number: DYNJ69129, DYNJ83090; t. NEURO IR PACK, Model Number: DYNJ35066I, DYNJ35066J, DYNJ60701A, DYNJ60701B, DYNJ60701C; u. NEURO PACK, Model Number: DYNJ43934A, DYNJ61798D, DYNJ66241, DYNJ66241A, DYNJ66241B, DYNJ66241C, DYNJ66241D, DYNJ68956A, DYNJ68956B; v. NEURO RADIOLOGY PACK, Model Number: DYNJ51107A, DYNJ59903A, DYNJ59903B; w. NEURO TRAY, Model Number: DYNJ67075, DYNJ67075A; x. PACK PERCUTANEOUS ANGIO CHRG, Model Number: DYNJ60112A; y. PEDI ANGIO PACK-LF, Model Number: PHS41743B; z. PEDIATRIC CATH ANGIO PACK, Model Number: DYNJ54755C; aa. RADIOLOGY NEURO DRAPE PAC, Model Number: DYNJ61449; bb. RO-DIEP PACK, Model Number: DYNJ82393A;

MEDLINE INDUSTRIES, LP - Northfield

Class I - Dangerous

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

May 15, 2023 Other Medical Devices Nationwide View Details →

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

May 15, 2023 Other Medical Devices Nationwide View Details →

An issue with the Suction Coagulator product family may lead to fluid ingress into the handpiece. Fluid ingress can lead to intermittent device activation, non-activation, or self-activation when plugged into the electrosurgery unit (ESU).

Jun 15, 2023 Other Medical Devices Nationwide View Details →

Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ELECTROPHYSIOLOGY PACK-LF, Model Number: DYNJ0842825D; b. EMANUEL EP TRAY, Model Number: DYNJ49933I, DYNJ49933J; c. ENDO LASER ABLATION PK-LF, Model Number: DYNJ44808G; d. ENDO VASCULAR, Model Number: DYNJ51304B, DYNJ51304C; e. ENDO VASCULAR PACK, Model Numbers: DYNJ0678934D, DYNJ0678934F, DYNJ82567; f. ENDO VASCULAR PACK-LF, Model Number: DYNJ0676055N; g. ENDOVASCULAR, Model Numbers: DYNJ63343A, DYNJ63343B, DYNJ63343D, DYNJ63343F, DYNJ908880; h. ENDOVASCULAR CDS, Model Number: CDS983394I, CDS983394J, CDS983394K; i. ENDOVASCULAR IMF 88370-LF, Model Number: DYNJVB91067; j. ENDOVASCULAR KIT, Model Number: DYNJ906354D, DYNJ906354F; k. ENDOVASCULAR PACK, Model Number: DYNJ0678934I, DYNJ44934F, DYNJ905726C, DYNJ905726D; l. ENDOVASCULAR PACK-LF, Model Number: DYNJ42831F; m. ENDOVASCULAR -TEMPLE, Model Number: DYNJ67750, DYNJ67750A, DYNJ67750B, DYNJ67750C; n. ENDOVENOUS ABLATION PACK, Model Number: DYNJ80489; o. ENDOVENOUS BASIC PACK, Model Number: DYNJ48456C, DYNJ69108A; p. ENDOVENOUS PACK, Model Number: DYNJ83606; q. ENT FREE FLAP, Model Number: SYNJ910018B; r. EP ANGIO PACK, Model Number: DYNJ25749S; s. EP DRAPE PACK-LF, Model Number: DYNJ47645C; t. EP LAB, Model Number: DYNJ59392D, DYNJ59392F; u. EP PACER PACK, Model Number: DYNJ67770; v. EP PACK, Model Number: DYNJ23456K, DYNJ68019, DYNJ81716, DYNJ81716A, DYNJ81716B; w. EP PROCEDURE PACK, Model Number: DYNJ67771; x. EP TRAY, Model Number: DYNJ31928D; y. FEM POP BYPASS PACK-LF, Model Number: DYNJ53480F; z. FEM POP PACK, Model Number: DYNJ67487C; aa. FISTULA PACK, Model Number: DYNJ82711; bb. FISTULA SAVANNAH PACK, Model Number: DYNJ69943A; cc. GENERAL HEART, Model Number: DYNJ907915; dd. GROTH LASER VEIN CDS, Model Number: CDS984193O; ee. GV PERIPHERAL VASCULAR PACK, Model Number: DYNJ46590I, DYNJ46590J, DYNJ46590K; ff. GWINNETT ENDOVASCULAR WSTE MGT, Model Number: DYNJ68198; gg. HCP OPEN HEART ACCESSORY PACK, Model Number: DYNJ51925F; hh. HEART A PACK, Model Number: DYNJ0541930N; ii. HEART FAILURE PACK, Model Number: DYNJ64877B; jj. HEART FAILURE PK, Model Number: DYNJ55528A, DYNJ55528B, DYNJ55528C; kk. HEART PACK, Model Number: DYNJ48424A; ll. HEART VALVE PACK, Model Number: DYNJ58365C, DYNJ58365F, DYNJ58365G, DYNJ58365J; mm. HEART VEIN NYC-ARTERIAL PACK, Model Number: DYNJ62851B; nn. HEART VEIN NYC LASER ABLATION, Model Number: DYNJ62850A; oo. HMT TAVR, Model Number: DYNJ905495D, DYNJ905495F; pp. HMT VEIN PACK, Model Number: DYNJ38756B; qq. HP MINOR VASCULAR, Model Number: DYNJ907571A, DYNJ907571B; rr. INTERVENTIONAL RAD L J-LF, Model Number: DYNJ40215C; ss. INTERVENTIONAL RADIOLOGY, Model Number: DYNJ52756A; tt. INTERVENTIONAL RADIOLOGY PACK, Model Number: DYNJ47138B; uu. IR ANGIOGRAM LIGHT PK, Model Number: DYNJ82858A; vv. IR ANGIOGRAM PACK, Model Number: DYNJ82859A; ww. JVL-PACK VNUS CLOSURE, Model Number: DYNJ66076; xx. KIT CARDIAC ROBOTIC MID CAB, Model Number: DYKMBNDL22C; yy. KIT LB OPEN HEART, Model Number: CDS840487G; zz. KIT MAJOR VASCULAR, Model Number: DYNJ907262, DYNJ907262B; aaa. KIT NEURO CAROTID SETUP, Model Number: DYKMBNDL148A; bbb. KIT OPEN HEART, Model Number: DYNJ906113; ccc. KIT OR AORTOGRM ANGIOPLAST PHT, Model Number: DYNJ906086B; ddd. KIT VASCULAR AAA REPAIR, Model Number: DYKMBNDL23; eee. KIT VASCULAR ACCESS PHT, Model Number: DYNJ906098, DYNJ906098A; fff. KIT VASCULAR CAROTID, Model Number: DYKMBNDL118A; ggg. KIT VASCULAR RF, Model Number: DYNJ906960A; hhh. KT TAVR PACK, Model Number: DYNJ56283C, DYNJ56283D, DYNJ56283F; iii. LASER ABLATION, Model Number: DYNJ48962B; jjj. LASER AND VEIN PACK, Model Number: DYNJ38995C, DYNJ67725; kkk. LASER PACK, Model Number: DYNJ65294; lll. LB OPEN HEART BOX, Model Number: DYNJ905859B; mmm. LEE VEIN PACK, Model Number: DYNJ54906B; nnn. LEG VASCULAR SUPPLY -LF, Model Number: D

MEDLINE INDUSTRIES, LP - Northfield

Class I - Dangerous

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

May 15, 2023 Other Medical Devices Nationwide View Details →

Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ABLATION/DRAINAGE PACK, Model Number: DYNJ53658B; b. BASIC BIOPSY TRAY, Model Number: DYNDH1534; c. BIOPSY PACK, Model Number: DYNDH1124, DYNJ50485; d. BIOPSY PACK-LF, Model Number: DYNJ0747885G; e. BIOPSY RAD CT, Model Number: DYNJ59752A; f. BIOPSY TRAY, Model Number: DYNDH1748, DYNJ34637F, DYNJ34637G, DYNJ43076, DYNJ43076A, DYNJ62690; g. BIOPSY WITH PROB COVER WRO-LF, Model Number: DYNJ42307A; h. BREAST BIOPSY KIT, Model Number: DYNDA1224B; i. BREAST BIOPSY TRAY, Model Number: DYNDH1266, DYNDH1302, DYNDH1345A, DYNDH1677; j. CABARRUS BIOPSY TRAY, Model Number: DYNDH1670; k. CORE BIOPSY PACK-LF, Model Number: DYNJ42752A; l. GENERAL BIOPSY PACK, Model Number: P365500; m. IGT BIOPSY PACK-LF, Model Number: DYNJ38616A; n. IR BIOPSY PACK, Model Number: DYNJ63688I; o. PROSTATE BIOPSY, Model Number: DYNJVB91015A; p. PROSTATE BIOPSY PACK, Model Number: DYNJ56578; q. RENAL BIOPSY TRAY, Model Number: SPEC0168; r. REVAMP BIOPSY TRAY, Model Number: DYNDH1147A; s. SOFT TISSUE BIOPSY, Model Number: DYNDH1750; t. THYROID BIOPSY TRAY, Model Number: DYNDH1288; u. U/S CORE BIOPSY KIT, Model Number: DYNDH1121C; v. UL BIOPSY TRAY, Model Number: DYNDH1778; w. ULTRASOUND BIOPSY, Model Number: DYNDH1542B; x. ULTRASOUND BREAST BIOPSY, Model Number: DYNDH1496A; y. ULTRASOUND CORE BIOPSY TRAY, Model Number: DYNDH1786; z. US BREAST BIOPSY PACK, Model Number: DYNJ61992B;

MEDLINE INDUSTRIES, LP - Northfield

Class I - Dangerous

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

May 15, 2023 Other Medical Devices Nationwide View Details →
Class I - Dangerous

Image intensifiers on systems, used to provide fluoroscopic/digital spot images can become detached if the systems encounter a large impact force when moved, which may result in the image intensifier falling, which could lead to injuries such as fractures, hematoma, contusion, bruise, pain.

May 15, 2023 Other Medical Devices Nationwide View Details →

Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. MULTI-LUMEN CVC BUNDLE KIT, Model Number: ECVC475; b. MULTI-LUMEN CVC INSERTION BUNDLE, Model Number: ECVC3900; c. MULTIMED 16G 1L 20CM CVC STOCK+BUNDLE US, Model Number: STCVC20US; d. MULTIMED 7F 2L 16CM STOCK + BUNDLE US, Model Number: STCVC21US; e. MULTIMED 7F 3L 16CM CVC BUNDLE, Model Number: ECVC6585A; f. MULTIMED 7F 3L 20CM PI, Model Number: ECVC7235A; g. MULTIMED 7FR 16CM CVC STK + BUNDLE-US, Model Number: STCVC03US; h. MULTIMED 7FR 3L 16CM CVC BUNDLE, Model Number: ECVC6655A; i. MULTIMED 7FR 3L 20CM CVC BUNDLE-US, Model Number: ECVC7935; j. MULTIMED 7FR 3L 20CM CVC STK + BUNDLE-US, Model Number: STCVC04US; k. MULTIMED 7FR, 20CM, 3L CVC BUNDLE, Model Number: ECVC7670; l. MULTIMED 8.5F 20CM QUAD CVC BUNDLE, Model Number: ECVC7090; m. MULTIMED 8.5FR 16CM QUAD CVC BUNDLE, Model Number: ECVC6930; n. MULTIMED 8.5FR 2L 16CM CVC STK+BUNDLE-US, Model Number: STCVC13US; o. NEURO CATH PACK (NCLUA)227-LF, Model Number: DYNJ47646D, DYNJ47646F, DYNJ47646G, DYNJ47646I; p. O.R. DOUBLE LUMEN INSERTION TRAY, Model Number: ECVC8010; q. OLEAN GENERAL CVC BUNDLE, Model Number: ECVC4615; r. OR ANGIO PACK, Model Number: DYNJ59184B; s. OR ANGIOGRAM, Model Number: DYNJ909267; t. OR ANGIOGRAPHY DRAPE, Model Number: DYNJ906297D; u. OR ANGIOGRAPHY PACK, Model Numbers: DYNJ67245A, DYNJ67245B; v. OR PERCUTANEOUS CATH PACK, Model Number: DYNJ63372A, DYNJ63372B, DYNJ63372C, DYNJ63372D; w. OR VANTEX 7FR 3L 16CM CVC, Model Number: ECVC6665; x. OR VASCULAR ANGIO PACK, Model Number: DYNJ69763, DYNJ69763A; y. PACK CARDIAC CATH, Model Number: DYNJ65481; z. PACK PERCUTANEOUS ANGIO CHRG, Model Number: DYNJ60112B; aa. PEDIATRIC CATH ANGIO PACK, Model Number: DYNJ54755G, DYNJ54755I; bb. PEDIATRIC CATH PACK-LF, Model Number: DYNJ0843244K; cc. PERCUTANEOUS ANGIO PACK-LF, Model Number: DYNJ57645C; dd. PERCUTANEOUS PACK, Model Number: DYNJ46035C, DYNJ46035D; ee. PERMA CATH PACK, Model Number: DYNJ62007A; ff. PI CVC BUNDLE, VANTEX 3L, 16CM, Model Number: ECVC3665; gg. PI CVC BUNDLE, VANTEX 3L, 20CM, Model Number: ECVC6190; hh. PI VANTEX 7FR 16CM 3L CVC BUNDLE-MAXPLUS, Model Number: ECVC4380; ii. PI VANTEX 7FR 16CM 3L CVC-MicroClave, Model Number: ECVC5655; jj. PI VANTEX 7FR 20CM 3L CVC-MicroClave, Model Number: ECVC5650; kk. PI VANTEX 8.5FR 16CM 4L CVC-MicroClave, Model Number: ECVC5660; ll. PI VANTEX 8.5FR 20CM 4L CVC-MicroClave, Model Number: ECVC5685; mm. PICC LINE PACK-LF, Model Number: DYNJ0275614F; nn. PK, RADIOLOGY, Model Number: DYNJ43894B; oo. PORT A CATH PACK, Model Number: DYNJ59307F; pp. PORT PACK, Model Number: DYNJ58162; qq. PORTACATH PACK, Model Number: DYNJ51240A; rr. QUAD LUMEN CVC BUNDLE 8.5F, 16CM, Model Number: ECVC3700; ss. QUAD LUMEN CVC BUNDLE, 8.5F, 20CM, Model Number: ECVC4995; tt. QUAD LUMEN CVC INSERTION BUNDLE, Model Numbers: ECVC5025, ECVC4135; uu. QUAD LUMEN KIT, Model Number: ECVC5820; vv. RADIOFREQUENCY ABLATION PACK, Model Number: DYNJ65913; ww. RADIOLOGY PACK, Model Numbers: DYNJ41190, DYNJ43894A, DYNJ44087A, DYNJ44524F, DYNJ52806C; xx. RADIOLOGY PACK 108402-LF, Model Number: DYNJVB1000; yy. RR-ADULT ECMO PACK, Model Number: DYNJ69742, DYNJ69742B; zz. SHEATH INTRODUCER BUNDLE, Model Number: ECVC2930, ECVC5835; aaa. SK-ANGIO TRAY-LF, Model Number: DYNJ82030; bbb. SK-INTERVENTIONAL TRAY-LF, Model Number: DYNJ82041; ccc. SPECIAL PROCEDURE CATH LAB PK, Model Number: DYNJ68729; ddd. SPECIAL PROCEDURE PACK, Model Number: DYNJ38314G; eee. SPECIAL PROCEDURE PACK-LF, Model Number: DYNJ0416535AA, DYNJ0416535W, DYNJ0458661C; fff. SPECIAL PROCEDURE PK-LF, Model Number: DYNJ0604508R; ggg. SPECIAL PROCEDURES, Model Number: DYNJ23288C; hhh. STANDARD ANGIO TRAY MV, Model Number: DYNJ67136A; iii. STD, AVA ,3XI ,3L 8.5F KIC, Model Number: ECVC7465A; jjj. STD, AVA, 3L, 9F, HF, KIC, Model Number: ECVC810

MEDLINE INDUSTRIES, LP - Northfield

Class I - Dangerous

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

May 15, 2023 Other Medical Devices Nationwide View Details →

Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ANGIO, Model Number: DYNJ902507B; b. ANGIO BASIN SET, Model Numbers: DYNJ46043D, DYNJ46043F; c. ANGIO CATH COMBINED PACK, Model Numbers: DYNJ43609K, DYNJ43609L, DYNJ43609M, DYNJ43609N; d. ANGIO DRAPE PACK, Model Number: DYNJ17624B, DYNJ44320F; e. ANGIO DRAPE SPEC PROC PACK, Model Number: DYNJ47951A; f. ANGIO LEFT HEART PACK, Model Number: DYNJ40632C; g. ANGIO PACK, Model Numbers: DYNJ30141, DYNJ34361, DYNJ42903B, DYNJ43661B, DYNJ47226A, DYNJ50624A, DYNJ51239A, DYNJ58111C, DYNJ58126A, DYNJ62299, DYNJ62544, DYNJ65043A, DYNJ66398A, DYNJ66398B; h. ANGIO PACK 2-A, Model Number: DYNJ60507A; i. ANGIO PACK-LF, Model Numbers: DYNJ0373279L, DYNJ0373279M; j. ANGIO TRAY, Model Numbers: DYNJ46153A, DYNJ46153B, DYNJ52121; k. ANGIO TRAY W/CHLORAPREP, Model Number: DYNJ62742; l. ANGIO/PICC PACK, Model Number: DYNJ36049; m. ANGIOGRAM, Model Number: DYNJ0149444M; n. ANGIOGRAM PACK, Model Numbers: DYNJ45007, DYNJ47004C, DYNJ66244; o. ANGIOGRAM TRAY, Model Number: DYNJ33638K; p. ANGIOGRAPHY DRAPE PACK, Model Numbers: DYNJ49621B, DYNJ63060A, DYNJ63684F, DYNJ68065, DYNJ68065A, DYNJT2344B; q. ANGIOGRAPHY DRAPE PACK-LF, Model Numbers: DYNJ28067G, DYNJVB1135A; r. ANGIOGRAPHY DRP PK PEDI CATH, Model Numbers: 00-401318L, 00-401318M; s. ANGIOGRAPHY OR, Model Number: CDS984944C; t. ANGIOGRAPHY PACK, Model Numbers: DYNJ44293D, DYNJ47906, DYNJ55252B, DYNJ57498, DYNJ65190C, DYNJ66476, DYNJC2371G; u. ANGIOGRAPHY PACK-LF, Model Number: DYNJ0854485T; v. ANGIOPLASTY PACK-LF, Model Numbers: DYNJ43203F, DYNJ64655A; w. CATH LAB PACK, Model Number: DYNJ65185; x. CLOVIS CATH LAB PACK, Model Number: DYNJ62379; y. CUSTOM ANGIO TRAY, Model Number: DYNJ41649F; z. CVOR ANGIOGRAPHY PACK-LF, Model Number: DYNJ42367A; aa. DASHTI-YAO NEURO ANGIO-LF, Model Number: DYNJ33457C; bb. DBD-ANGIO TRAY, Model Number: DYNJ68758; cc. DBD-CATH PACK, Model Number: DYNJ63527; dd. DBD-CLOVIS CATH LAB PACK, Model Number: DYNJ62379; ee. DEPAUL ANGIO PACK, Model Number: DYNJ19939M; ff. EH VASCULAR ANGIO, Model Number: DYNJ49931F; gg. ENDOVASCULAR KIT, Model Number: DYNJ906354C; hh. EP ANGIOGRAPHY PACK, Model Number: DYNJ24225K; ii. FEMORAL ANGIOGRAPY SET UP, Model Number: DYNJ61015B; jj. FS ANGIO, Model Number: DYNJ42499C; kk. GENERAL ANGIO PACK, Model Number: DYNJ57760B; ll. HH ANGIO PACK, Model Number: DYNJ59465B; mm. IPMC ANGIOGRAPHY PACK-LF, Model Number: DYNJ0806254D; nn. IR MINOR ANGIO PACK, Model Number: DYNJ37665B; oo. KENNESTONE ANGIO, Model Number: WK100B; pp. MH HOOD CARDIAC ANGIO, Model Numbers: DYNJ49884B, DYNJ49884F; qq. MV-IR ANGIO DRAPE PACK-LF, Model Number: DYNJ41553D; rr. OR ANGIO PACK, Model Number: DYNJ60319A; ss. OR ANGIOGRAPHY PACK, Model Number: DYNJ67245; tt. PACK,BASIC ANGIO, Model Number: DYNJ65482A; uu. PEDI ANGIO PACK-LF, Model Number: PHS41743D; vv. PEDIATRIC CATH ANGIO PACK, Model Numbers: DYNJ54755D, DYNJ54755F; ww. PERCUTANEOUS ANGIO CHRG, Model Number: DYNJ60112; xx. PERCUTANEOUS ANGIO PACK-LF, Model Numbers: DYNJ57645A, DYNJ57645B; yy. PORT PACK, Model Number: DYNJ61747A; zz. SUNSHINE PACK, Model Number: DYNJ64830; aaa. SURGERY ANGIO PACK-LF, Model Number: DYNJ66500; bbb. VASCULAR ANGIO PACK-LF, Model Numbers: DYNJ0201109AG

MEDLINE INDUSTRIES, LP - Northfield

Class I - Dangerous

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

May 15, 2023 Other Medical Devices Nationwide View Details →