Infusion Pumps

πŸ₯ Medical Devices β€’ 4,262 recalls

Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).

Oct 29, 2025 Infusion Pumps View Details β†’

Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).

Oct 29, 2025 Infusion Pumps View Details β†’

Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).

Oct 29, 2025 Infusion Pumps View Details β†’

Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes.

Sep 26, 2025 Infusion Pumps Nationwide View Details β†’

If infusion pump is dropped or severely jarred this may damage the pump module bezel assembly, which can cause under-infusion, over-infusion, unregulated flow, or pump module failure to calibrate; so dropped/jarred pumps should be removed from use, tested, and inspected by qualified service personnel prior to reuse; tip sheet, cleaning and disinfecting procedure and reference guide updated.

Oct 17, 2025 Infusion Pumps Nationwide View Details β†’
Class I - Dangerous

As of August 6, 2025, Medtronic has received eleven reports of VitalFlow Consoles displaying an E70 error code during normal operation. When this occurs, the touch screen may become temporarily unresponsive and go blank for up to two minutes before recovering to full functionality. Importantly, the console continues to maintain set pump speed and function throughout.

Oct 3, 2025 Infusion Pumps Nationwide View Details β†’

Some of the VacuetteΒΏ CAT Serum Separator Clot Activator tubes were manufactured without gel separator, which could yield erroneous assay results and require the patient to return to the lab for recollection or repeat testing. This may result in delayed diagnosis, cause a delay in clinical decision-making or treatment and in some rare cases, yield incorrect results from less stable parameters.

Aug 19, 2025 Infusion Pumps Nationwide View Details β†’

MEDLINE convenience kits labeled as: 1) C-SECTION OR 30 CDS, REF CDS820075W; 2) C-SECTION, REF CDS984261J; 3) C-SECTION CDS, REF CDS985282F; 4) C-SECTION PACK, REF DYNJ02577D; 5) C-SECTION PACK-LF, REF DYNJ0536924U; 6) C-SECTION PACK-LF, REF DYNJ0551169V; 7) C-SECTION PACK-LF, REF DYNJ0551409P; 8) C-SECTION PACK-LF, REF DYNJ07836R; 9) C-SECTION, REF DYNJ14103C; 10) C-SECTION PACK, REF DYNJ19417R; 11) C-SECTION PACK-LF, REF DYNJ33059B; 12) C-SECTION PACK SC-LF, REF DYNJ38063D; 13) C-SECTION PACK SC-LF, REF DYNJ38700G; 14) C-SECTION PACK-LF, REF DYNJ38845D; 15) C-SECTION PACK-LF, REF DYNJ38845F; 16) C-SECTION PACK, REF DYNJ44679L; 17) C-SECTION DELIVERY PACK-LF, REF DYNJ47808F; 18) C SECTION PACK, REF DYNJ48087I; 19) C-SECTION I, REF DYNJ51354B; 20) C-SECTION SAFETY PACK, REF DYNJ52481B; 21) C-SECTION SMMC, REF DYNJ59457B; 22) C-SECTION PACK, REF DYNJ59825A; 23) PK CUST C-SECTION ST MICH, REF DYNJ60544C; 24) C SECTION PACK, REF DYNJ64377D; 25) C-SECTION PACK, REF DYNJ64505B; 26) C SECTION SHARED, REF DYNJ64775C; 27) LDRP-C SECTION PACK-LF, REF DYNJ64834A; 28) LDRP-C SECTION PACK-LF, REF DYNJ64834B; 29) C-SECTION PACK-LF, REF DYNJ65031D; 30) C SECTION PK, REF DYNJ65403A; 31) C SECTION PACK-LF, REF DYNJ65765A; 32) C-SECTION PACK-LF, REF DYNJ69445; 33) C-SECTION PACK-LF, REF DYNJ69445A; 34) C SECTION DELIVERY PACK, REF DYNJ81604A; 35) C SECTION DELIVERY PACK, REF DYNJ81604B; 36) C SECTION PACK, REF DYNJ82949; 37) C-SECTION ADD ON PACK, REF DYNJ83507; 38) C-SECTION PACK, REF DYNJ83980; 39) C SECTION ACCESS, REF DYNJ85612; 40) ISSAQUAH C-SECTION PACK-LF, REF DYNJ85770; 41) C-SECTION PACK, REF DYNJ86173; 42) C-SECTION, REF DYNJ900266F; 43) C-SECTION, REF DYNJ903865D; 44) C-SECTION, REF DYNJ904612G; 45) C-SECTION, REF DYNJ904612I; 46) C-SECTION, REF DYNJ904653G; 47) C-SECTION, REF DYNJ904697F; 48) CDS C-SECTION CH, REF DYNJ906263D; 49) C SECTION, REF DYNJ908327; 50) C-SECTION -LF, REF DYNJ9932207R; 51) C-SECTION -LF, REF DYNJ9932207S; 52) C-SECTION PACK, REF DYNJV0322A; 53) GP-C SECTION PACK-LF, REF PHS396980007C.

Medline Industries

Class I - Dangerous

Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing SafeAir Smoke Evacuation Pencils. Stryker Instruments has expanded the scope of their recall of SafeAir Smoke Evacuation Pencils previously initiated in October 2024, adding an additional 47 lots to the scope of the recall. The initial recall was due to the potential for product to activate without manual input when plugged into a power source or remain active after buttons are released.

Sep 30, 2025 Infusion Pumps Nationwide View Details β†’

Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes.

Sep 26, 2025 Infusion Pumps Nationwide View Details β†’

When appending a care plan that contains one or more wave medication orders, the occurrence and frequency of the appended orders may not match the intended schedule.

Sep 17, 2025 Infusion Pumps Nationwide View Details β†’

The barcode orientation on affected devices causes incorrect scanning order of tubes within the allergen holder wedge. When using an IMMULITE 2000 / IMMULITE 2000 XPi instrument in combination with a Zebra barcode scanner, the instrument will not correctly recognize the position of tubes within the allergen holder wedge.

Oct 6, 2025 Infusion Pumps Nationwide View Details β†’

Insulin pump includes a vibration motor that gives tactile feedback for any alerts, alarms, or malfunctions. Pump may exhibit false vibration motor failure due to a software issue causing Malfunction 12: "Pump cannot operate, the mobile app can no longer receive data from the pump. Insulin delivery and any active CGM Sessions have been stopped", which could result in hyperglycemia.

Oct 6, 2025 Infusion Pumps Nationwide View Details β†’

Issue 1: The potential for unintentional continued gantry/couch movement when a specific button series is used requiring use of manual stop. Issue 2. When performing a helical/Axial scan with ORI (Dose Right index)/ DOM (Dose Modulation), the WED (Water Equivalent Diameter) value might set itself to zero, and this may lead to an insufficient dose setting after the surview. If operator misses the insufficient dose and the WED value in User Interface and continues with the subsequent helical/Axial scans, then the obtained images will be noisy due to low dose setting. Issue 3: Due to a software failure, the ECG wave file is not saved. As a result, the cardiac offline image reconstruction fails due to the missing ECG wave file, and the user might rescan the patient. Issue 4: This issue is software fault in which the patient orientation will be changed to NULL under specific random scenarios resulting in radiation being delivered from the wrong orientation (surview scan) or in the wrong position (clinical scan) and will generate incorrect and undiagnosable surview/clinical images. Patients may be rescanned for surview and/or clinical images. Issue 5: During scanning, the preview image display is not consistent, the images are not arriving at a fixed rate, skipping images from time to time during scanning. The obtained images might not support making the clinical diagnosis and the user might decide to re-scan the patient. Issue 6: If a user presses the left and middle/right mouse buttons together or afterwards in a short time, both commands are executed and an incorrect auto ROI is created. This ROI coordinates won t be assigned as the object is empty. As a result, the threshold of contrast level will not be reached in the UI and this will prevent the system from automatically triggering the subsequent clinical scan. There is potential safety risk identified for additionally tracker shots and/or rescan of a patient when the clinical scan is not triggered. This issue only affects the manual ROI process.

Sep 25, 2025 Infusion Pumps View Details β†’