Alcon CUSTOM-PAK which is supposed to contain a 27G Anterior Chamber Cannula (27G x 7/8 in) actually contains a 27G Sharp Tip Needle

May 16, 2014 Infusion Pumps Nationwide View Details →

If the universal ingredient (UI) in an active configuration is changed using the Configuration Editor, a flush of the outlet pump tube will not be initiated by the software. It could result in the original UI remaining in the tube which could be delivered into the next bag.

Jun 10, 2014 Infusion Pumps Nationwide View Details →

There is a potential fire hazard of certain Lithium-Ion batteries in the computers used in the original manufacturing or as spare parts between October 2010 and April 2011 for the Siemens Mobilett XP Digital mobile X-ray System, which might occur at any time with higher probability while the system is being charged and connected to the main power supply.

May 9, 2014 Infusion Pumps Nationwide View Details →

There is a potential risk when using LANTIS OIS System client software with operating systems for which it has not been validated and released, resulting in incorrectly stored data, such as treatment records, and LANTIS database corruption.

May 6, 2014 Infusion Pumps Nationwide View Details →

Under certain conditions loose ProCell/CleanCell aspiration tube filters may cause: consecutive discrepant results; sipper alarm; foam on reservoirs and system reagent alarms.

May 21, 2014 Infusion Pumps Nationwide View Details →

When using CMA, if the user hovers the mouse pointer exactly above the direction dropdowns and then uses the mouse thumbwheel or touchpad scroll bar, the direction selection might change when the intention was only to move the mouse to a different area of the screen.

May 23, 2014 Infusion Pumps Nationwide View Details →

Under certain conditions loose ProCell/CleanCell aspiration tube filters may cause: consecutive discrepant results; sipper alarm; foam on reservoirs and system reagent alarms.

May 21, 2014 Infusion Pumps Nationwide View Details →

Under certain conditions loose ProCell/CleanCell aspiration tube filters may cause: consecutive discrepant results; sipper alarm; foam on reservoirs and system reagent alarms.

May 21, 2014 Infusion Pumps Nationwide View Details →

On 06/08/2011, BioDerm, Inc. issued a voluntary recall of a component (Smith and Nephew skin wipes) used in the BioDerm Liberty 3.0 External Male Catheter, BioDerm Liberty Pouch Clean & Dry External Male Catheter and BioDerm Safe n' Dry. Potential bacterial contamination of Smith and Nephew skin wipes by one of their contract manufacturers.

May 31, 2011 Infusion Pumps Nationwide View Details →

Small Bone Innovations (SBI) is recalling non-sterile RingFIX Olive Wires labeled as item #451-3004 Drill tip 1.8 mm diameter 400mm olive k-wire packaged with item #451-3005 Bayonet tip 1.8mm diameter 400mm olive k-wire inside.

Apr 7, 2014 Infusion Pumps Nationwide View Details →

There is the potential for the door roller assembly on the Plum LifeCare 5000 Series and Plum XL families of infusers to break. In the event of a broken door roller pin, the door cannot appropriately lock the cassette in the right position. Depending on the conditions of a broken door roller pin, a number of events can occur. The door cannot be closed or a cassette/door alarm or a false occlusion

Jan 24, 2014 Infusion Pumps Nationwide View Details →