Pump was found to be constructed from crimp connectors that do not meet the fixation wiring requirements and can cause failure of the device to operate or electric shock or burn to the user.
Infusion Pumps
🏥 Medical Devices • 4,262 recalls
PRIMUS HI, Digital Linear Accelerator, Model No. 04504200 Product Usage: The intended use of the device is to deliver x-ray radiation for therapeutic treatment of cancer.
Siemens Medical Solutions USA
Control Console software has been updated to reduce the risk for collision when delivering automatically sequenced treatments with automatic movements of the gantry and/or the treatment table.
Certain Flex Connectors supplied with Halyard Closed Suction Kits with Flex Connector may become loose or disconnect before use or during use.
MEVATRON M2 / PRIMUS Mid-Energy, Digital Linear Accelerator, Model No. 01940035 Product Usage: The intended use of the device is to deliver x-ray radiation for therapeutic treatment of cancer.
Siemens Medical Solutions USA
Control Console software has been updated to reduce the risk for collision when delivering automatically sequenced treatments with automatic movements of the gantry and/or the treatment table.
ONCOR Impression , Digital Linear Accelerator, Model No. 05857920 Product Usage: The intended use of the device is to deliver x-ray radiation for therapeutic treatment of cancer.
Siemens Medical Solutions USA
Control Console software has been updated to reduce the risk for collision when delivering automatically sequenced treatments with automatic movements of the gantry and/or the treatment table.
Certain Flex Connectors supplied with Halyard Closed Suction Kits with Flex Connector may become loose or disconnect before use or during use.
ONCOR Impression Plus, Digital Linear Accelerator, Model No. 05857912 Product Usage: The intended use of the device is to deliver x-ray radiation for therapeutic treatment of cancer.
Siemens Medical Solutions USA
Control Console software has been updated to reduce the risk for collision when delivering automatically sequenced treatments with automatic movements of the gantry and/or the treatment table.
ONCOR Avant-garde, Digital Linear Accelerator, Model No. 05863472 Product Usage: The intended use of the device is to deliver x-ray radiation for therapeutic treatment of cancer.
Siemens Medical Solutions USA
Control Console software has been updated to reduce the risk for collision when delivering automatically sequenced treatments with automatic movements of the gantry and/or the treatment table.
ONCOR Expression, Digital Linear Accelerator, Model No. 07360717 Product Usage: The intended use of the device is to deliver x-ray radiation for therapeutic treatment of cancer.
Siemens Medical Solutions USA
Control Console software has been updated to reduce the risk for collision when delivering automatically sequenced treatments with automatic movements of the gantry and/or the treatment table.
Pump was found to be constructed from crimp connectors that do not meet the fixation wiring requirements and can cause failure of the device to operate or electric shock or burn to the user.
The implant size is incorrectly etched on the implant. The size listed on the box is correct.
Baker Jejunostomy Tubes: Product Code Equivalent Code (a) 655300160 655316 (b) 655500200 655520
Teleflex Medical Europe
These products contain latex, but the following statement is not included on any level of product packaging: Caution: This Product Contains Natural Rubber Latex Which May Cause Allergic Reactions.
Users manuals not supplied with 4800-00T US Rapid Therapy System
Following the completion of sterilization cycle(s) of the impacted Hex Driver, the epoxy color band on the impacted Hex Driver can migrate down the shaft and/or potentially onto the sterilization tray or caddy.
LeadCare Plus Blood Lead Analyzer Part Number: 82-0001 Intended for the quantitative measurement of lead in a whole blood sample.
Magellan Diagnostics
The incorrect placement of AA batteries into certain LeadCare Plus Blood Lead Analyzer may cause the batteries to overheat, and the chance that a user could burn their fingers if the batteries are removed while hot.
Certain lots of the spinal cement may contain incorrect amounts of contrast medium so that the product is difficult or impossible to visualize on x-ray.
Elecsys BRAHMS PCT Immunoassay for the in vitro quantitative determination of PCT (procalcitonin) in human serum and plasma (K2 and K3 EDTA, Li-Heparin).
Roche Diagnostics
Product exhibits a decreased recovery of patient samples on the cobas e 801 module compared to the MODULAR ANALYTICS E 170, cobas e 411, 601, and 602 analyzers.
Syngo.via. Medical Device Software. Picture archiving and communications system.
Siemens Medical Solutions USA
A software functionality in the report sections Findings Information and Summary of Measured Findings is not performing properly. The system will use the original values instead of displaying and saving corrected/modified values. Outdated information could be sent to the referring physician when creating the formal report in the reporting system.
Product reportedly shutting down during use.
DATEX-OHMEDA AISYS CS2 ALADIN2 CASSETTE Cassettes are intended to be used to deliver anesthetic agent.
GE Healthcare
Non-Conforming devices were shipped from the service center without proper evaluation and therefore may be nonconforming.