Drill Pin (drill bit) is not compatible with the Drill Template included in the kit due to a packaging error, result in a surgical delay and may cause soft tissue damage if a larger incision is required to accommodate an alternative form of fixation. Additionally, there is a potential for adverse tissue reaction if the surgeon attempts to use the guide regardless of tight fit and plastic debris is created and ends up in the wound

Aug 30, 2022 Implants & Prosthetics Nationwide View Details →

A MK4 Tibial Bearing was supplied with the intention to mate with the Tibial Metal Casing in-situ. However, the device in-situ was a MK3 Tibial Metal Casing. The supplied MK4 tibial bearing was not exchangeable for the MK3 tibial bearing. The surgeon needed to complete the surgery by re-assembling and re-inserting the extracted MK3 tibial bearing.

Aug 24, 2022 Implants & Prosthetics View Details →

GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. ACUMATCH GXL 0 DEGREE LINER 28MM SZ E, REF 130-28-25 b. ACUMATCH GXL 0 DEGREE LINER 28MM SZ F, REF 130-28-26 c. ACUMATCH GXL 0 DEGREE LINER 28MM SZ G, REF 130-28-27 d. ACUMATCH GXL 0 DEGREE LINER 28MM SZ H, REF 130-28-28 e. ACUMATCH GXL 0 DEGREE LINER 28MM SZ J, REF 130-28-29 f. ACUMATCH GXL 0 DEGREE LINER 32MM SZ G, REF 130-32-27 g. ACUMATCH GXL 0 DEGREE LINER 32MM SZ H, REF 130-32-28 f. ACUMATCH GXL 0 DEGREE LINER 32MM SZ J, REF 130-32-29 g. ACUMATCH GXL 0 DEGREE LINER 36MM SZ H, REF 130-36-28 h. ACUMATCH GXL 0 DEGREE LINER 36MM SZ J, REF 130-36-29 i. ACUMATCH GXL 0 DEGREE LINER 36MM SZ K, REF 130-36-30 j. ACUMATCH GXL 15 DEG +5 LAT LINER 28MM SZ E, REF 138-28-25 k. ACUMATCH GXL 15 DEG +5 LAT LINER 28MM SZ F, REF 138-28-26 l. ACUMATCH GXL 15 DEG +5 LAT LINER 28MM SZ G, REF 138-28-27 m. ACUMATCH GXL 15 DEG +5 LAT LINER 28MM SZ H, REF 138-28-28 n. ACUMATCH GXL 15 DEG +5 LAT LINER 28MM SZ J, REF 138-28-29 o. ACUMATCH GXL 15 DEG +5 LAT LINER 36MM SZ H, REF 138-36-28 p. ACUMATCH GXL 15 DEG +5 LAT LINER 36MM SZ J, REF 138-36-29 q. ACUMATCH GXL 15 DEG +5 LAT LINER 36MM SZ K, REF 138-36-30 r. ACUMATCH GXL 15 DEG +5 LAT LINER SZG 38MM, REF 138-36-27 s. ACUMATCH GXL 15DEG LINER 28MM SZ D, REF 132-28-24 t. ACUMATCH GXL 15DEG LINER 28MM SZ E, REF 132-28-25 u. ACUMATCH GXL 15DEG LINER 28MM SZ F, REF 132-28-26 v. ACUMATCH GXL 15DEG LINER 28MM SZ G, REF 132-28-27 w. ACUMATCH GXL 15DEG LINER 28MM SZ H, REF 132-28-28 x. ACUMATCH GXL 15DEG LINER 28MM SZ J, REF 132-28-29 y. ACUMATCH GXL 15DEG LINER 28MM SZ K, REF 132-28-30 z. ACUMATCH GXL 15DEG LINER 32MM SZ G, REF 132-32-27 aa. ACUMATCH GXL 15DEG LINER 32MM SZ H, REF 132-32-28 bb. ACUMATCH GXL 15DEG LINER 32MM SZ J, REF 132-32-29 cc. ACUMATCH GXL 15DEG LINER 32MM SZ K, REF 132-32-30 dd.ACUMATCH GXL 15DEG LINER 36MM SZ H, REF 132-36-28 ee. ACUMATCH GXL 15DEG LINER 36MM SZ J, REF 132-36-29 ff. ACUMATCH GXL 15DEG LINER 36MM SZ K, REF 132-36-30 gg. ACUMATCH GXL EXT COV LINER 28MM SZ E, REF 134-28-25 hh. ACUMATCH GXL EXT COV LINER 28MM SZ F, REF 134-28-26 ii. ACUMATCH GXL EXT COV LINER 28MM SZ G, REF 134-28-27 jj. ACUMATCH GXL EXT COV LINER 28MM SZ H, REF 134-28-28 kk. ACUMATCH GXL EXT COV LINER 28MM SZ J, REF 134-28-29 ll. ACUMATCH GXL EXT COV LINER 28MM SZ K, REF 134-28-30 mm. MCS GXL LINER 5/15 DEG 4448X28, REF 104-28-43 nn. MCS GXL LINER 5/15 DEG 5052X28, REF 104-28-44 oo. MCS GXL LINER 5/15 DEG 5458X28, REF 104-28-45 pp. MCS GXL LINER 5/15 DEG 5458X32, REF 104-32-45 qq. MCS GXL LINER 5/15 DEG 6064X32, REF 104-32-46 rr. MCS GXL LINER 5/15 DEG 6064X36, REF 104-36-46 ss. MCS GXL LINER 5/15 DEG 6670X36, REF 104-36-47

Exactech

Class I - Dangerous

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. NOVATION GXL LINER, NEUTRAL, 28MM ID, GROUP 1 CUPS, REF 130-28-51 b. NOVATION GXL LINER, NEUTRAL, 32MM ID, GROUP 2 CUPS, REF 130-32-52 c. NOVATION GXL LINER, NEUTRAL, 36MM ID, GROUP 3 CUPS, REF 130-36-53 d. NOVATION GXL LINER, NEUTRAL, 36MM ID, GROUP 4 CUPS, REF 130-36-54 e. NOVATION GXL LINER, NEUTRAL, 36MM ID, GROUP 5 CUPS, REF 130-36-55 f. NOVATION GXL LINER, +5 LAT 32MM ID, GROUP 3 CUPS, REF 136-32-53 g. NOVATION GXL LINER, +5 LAT 32MM ID, GROUP 4 CUPS, REF 136-32-54 h. NOVATION GXL LINER, +5 LAT 32MM ID, GROUP 5 CUPS, REF 136-32-55 i. NOVATION GXL LINER, +5LAT, 28MM G1-48/50MM CUPS, REF 136-28-51 j. NOVATION GXL LINER, +5LAT, 32MM G1-48/50MM CUPS, REF 136-32-51 k. NOVATION GXL LINER, +5LAT, 32MM G2-52/54MM CUPS, REF 136-32-52 l. NOVATION GXL LINER, +5LAT, 36MM G2-52/54MM CUPS, REF 136-36-52 m. NOVATION GXL LINER, +5LAT, 36MM G3-56/58MM CUPS, REF 136-36-53 n. NOVATION GXL LINER, +5LAT, 36MM G4-60/62MM CUPS, REF 136-36-54 o. NOVATION GXL LINER, +5LAT, 36MM G5-64/66/68MM CUPS, REF 136-36-55 p. NOVATION GXL LINER, 10 DEG FACE, 32MM ID, GRP 1 CUP, REF 138-32-51 q. NOVATION GXL LINER, 10 DEG FACE, 32MM ID, GRP 3 CUP, REF 138-32-53 r. NOVATION GXL LINER, 10 DEG FACE, 36MM ID, GRP 2 CUP, REF 138-36-52 s. NOVATION GXL LINER, 10 DEG FACE, 36MM ID, GRP 3 CUP, REF 138-36-53 t. NOVATION GXL LINER, 10 DEG FACE, 36MM ID, GRP 4 CUP, REF 138-36-54 u. NOVATION GXL LINER, 10 DEG FACE, 36MM ID, GRP 5 CUP, REF 138-36-55 v. NOVATION GXL LINER, 10 DEG FACE, REPLACED BY 138-36-52, REF 138-32-52 w. NOVATION GXL LINER, LIPPED 32MM ID GROUP 2 CUPS, REF 132-32-52 x. NOVATION GXL LINER, LIPPED ANT, 32MM ID, GROUP 1 CUPS, REF 132-32-61 y. NOVATION GXL LINER, LIPPED ANT, 36MM ID, GROUP 2 CUPS, REF 132-36-62 z. NOVATION GXL LINER, LIPPED ANT, 36MM ID, GROUP 3 CUPS, REF 132-36-63 aa. NOVATION GXL LINER, LIPPED ANT, 36MM ID, GROUP 4 CUPS, REF 132-36-64 bb. NOVATION GXL LINER, LIPPED, 36MM ID, GROUP 3 CUPS, REF 132-36-53 cc. NOVATION GXL LINER, LIPPED, 28MM ID, GROUP 1 CUPS, REF 132-28-51 dd. NOVATION GXL LINER, LIPPED, 28MM ID, GROUP 2 CUPS, REF 132-28-52 ee. NOVATION GXL LINER, LIPPED, 32MM ID GROUP 4 CUPS, REF 132-32-54 ff. NOVATION GXL LINER, LIPPED, 32MM ID, GROUP 3 CUPS, REF 132-32-53 gg. NOVATION GXL LINER, LIPPED, 32MM ID, GROUP 5 CUPS, REF 132-32-55 hh. NOVATION GXL LINER, LIPPED, 36MM ID GROUP 4 CUPS, REF 132-36-54 ii. NOVATION GXL LINER, LIPPED, 36MM ID, GROUP 5 CUPS, REF 132-36-55 jj. NOVATION GXL LINER, NEUTRAL, 28MM ID, GROUP 2 CUPS, REF 130-28-52 kk. NOVATION GXL LINER, NEUTRAL, 32MM ID, GROUP 3 CUPS, REF 130-32-53 ll. NOVATION GXL LINER, NEUTRAL, 32MM ID, GROUP 4 CUPS, REF 130-32-54 mm. NOVATION GXL LINER, NEUTRAL, 32MM ID, GROUP 5 CUPS, REF 130-32-55

Exactech

Class I - Dangerous

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. ACUMATCH 0 DEGREE LINER 28MM 46MM, REF 130-28-05; b. ACUMATCH 0 DEGREE LINER 28MM 48MM, REF 130-28-06; c. ACUMATCH 0 DEGREE LINER 28MM 50/52MM, REF 130-28-07; d. ACUMATCH 0 DEGREE LINER 28MM 54/56MM, REF 130-28-08; e. ACUMATCH 0 DEGREE LINER 28MM 58/64MM, REF 130-28-09; f. ACUMATCH 15 DEGREE LINER 22MM SZ D, REF 132-22-04; g. ACUMATCH 15 DEGREE LINER 22MM SZ E, REF 132-22-05; h. ACUMATCH 15 DEGREE LINER 22MM SZ F, REF 132-22-06; i. ACUMATCH 15 DEGREE LINER 22MM SZ G, REF 132-22-07; j. ACUMATCH 15 DEGREE LINER 22MM SZ H, REF 132-22-08; k. ACUMATCH 15 DEGREE LINER 28MM SZ E, REF 132-28-05; l. ACUMATCH 15 DEGREE LINER 28MM SZ F, REF 132-28-06; m. ACUMATCH 15 DEGREE LINER 28MM SZ G, REF 132-28-07; n. ACUMATCH 15 DEGREE LINER 28MM SZ H, REF 132-28-08; o. ACUMATCH 15 DEGREE LINER 28MM SZ J, REF 132-28-09; p. ACUMATCH 15 DEGREE LINER 28MM SZ K, REF 132-28-10; q. ACUMATCH 15 DEGREE LINER 32MM SZ G, REF 132-32-07; r. ACUMATCH 15 DEGREE LINER 32MM SZ H, REF 132-32-08; s. ACUMATCH 15 DEGREE LINER 32MM SZ J, REF 132-32-09; t. ACUMATCH 15 DEGREE LINER 32MM SZ K, REF 132-32-10; u. ACUMATCH EXT COV LINER 28MM 46MM, REF 134-28-05; v. ACUMATCH EXT COV LINER 28MM 48MM, REF 134-28-06; w. ACUMATCH EXT COV LINER 28MM 50/52MM, REF 134-28-07; x. ACUMATCH EXT COV LINER 28MM 54/56MM, REF 134-28-08; y. ACUMATCH EXT COV LINER 28MM 58/64MM, REF 134-28-09; z. ACUMATCH EXT COV LINER 28MM 66/70MM, REF 134-28-10; aa. ACUMATCH LAT LINER 28MM 46MM, REF 138-28-05; bb. ACUMATCH LAT LINER 28MM 48MM, REF 138-28-06; cc. ACUMATCH LAT LINER 28MM 50/52MM, REF 138-28-07; dd. ACUMATCH LAT LINER 28MM 54/56MM, REF 138-28-08; ee. ACUMATCH LAT LINER 28MM 58/64MM, REF 138-28-09; ff. ACUMATCH 15 DEG LINER, SZ F, 28MM ID, REF CSK-1663; gg. ACUMATCH 15 DEG LINER, SZ G, 28MM ID, REF CSK-1664; hh. ACUMATCH 15 DEG LINER, SZ H, 28MM ID, REF CSK-1665

Exactech

Class I - Dangerous

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

There is potential for unanticipated software anomalies to occur when using the Model 2868 Application loaded on the 3120 ZOOM LATITUTDE programmer when communicating with certain Boston Scientific transvenous defibrillators.

Jul 7, 2022 Implants & Prosthetics View Details →

There is potential for unanticipated software anomalies to occur when using the Model 2868 Application loaded on the 3120 ZOOM LATITUTDE programmer when communicating with certain Boston Scientific transvenous defibrillators.

Jul 7, 2022 Implants & Prosthetics View Details →

There is potential for unanticipated software anomalies to occur when using the Model 2868 Application loaded on the 3120 ZOOM LATITUTDE programmer when communicating with certain Boston Scientific transvenous defibrillators.

Jul 7, 2022 Implants & Prosthetics View Details →