MicroTip Pack Opener Assembly Potentially Not Removing or Replacing MicroTip Pack Caps on VITROSΒΏ 5600 and XT 7600 Integrated Systems, results may be delayed results if a pack becomes unusable

Mar 10, 2023 Diagnostic Equipment Nationwide View Details β†’

MicroTip Pack Opener Assembly Potentially Not Removing or Replacing MicroTip Pack Caps on VITROSΒΏ 5600 and XT 7600 Integrated Systems, results may be delayed results if a pack becomes unusable

Mar 10, 2023 Diagnostic Equipment Nationwide View Details β†’

There is a negative bias with urine patient samples and urine cortisol Quality Control (QC) results intermittently out of range low.

Mar 16, 2023 Diagnostic Equipment Nationwide View Details β†’

If, during the procedure, X-ray has been released and a reference image has been stored, the following issue may occur: If "Adjust C-arm to Ref" is activated when the C-Arm is positioned outside of the working range the C-Arm will reach the target position with an inaccuracy of 5-10 mm. As a result, the message Endposition reached will be displayed .Leading to unintended direction of the movement causing crushing of a patient, staff member, operator, or equipmen Live images may not match the previously stored reference images. Overlay images may be shown inaccurate on anatomy (e.g., DSA Roadmap workflow does not match real anatomy). This may cause e.g., a vessel perforation in DSA roadmap.

Feb 2, 2023 Diagnostic Equipment Nationwide View Details β†’

MicroTip Pack Opener Assembly Potentially Not Removing or Replacing MicroTip Pack Caps on VITROSΒΏ 5600 and XT 7600 Integrated Systems, results may be delayed results if a pack becomes unusable

Mar 10, 2023 Diagnostic Equipment Nationwide View Details β†’

There is a negative bias with urine patient samples and urine cortisol Quality Control (QC) results intermittently out of range low.

Mar 16, 2023 Diagnostic Equipment Nationwide View Details β†’

The software on the Infinity CentralStation drops peaks on narrow waveforms causing the Infinity M300 to fail to meet Frequency and Impulse Response requirements. In this condition, ECG waveforms with unusually narrow and/or high frequency QRS may be displayed or printed with QRS amplitudes intermittently lower than actual.

Apr 5, 2023 Diagnostic Equipment Nationwide View Details β†’

The software on the Infinity CentralStation drops peaks on narrow waveforms causing the Infinity M300 to fail to meet Frequency and Impulse Response requirements. In this condition, ECG waveforms with unusually narrow and/or high frequency QRS may be displayed or printed with QRS amplitudes intermittently lower than actual.

Apr 5, 2023 Diagnostic Equipment Nationwide View Details β†’

Due to potential software issue that may result in patient mix-up information.

Mar 8, 2023 Diagnostic Equipment Nationwide View Details β†’

Incorrect Number of Calibrator Levels (2) Set for the VITROS Immunodiagnostics Products Anti-SARS-CoV-2 Total N Antibody Calibrators in Assay Data Disks (ADD), resulting in delayed patients results

Mar 9, 2023 Diagnostic Equipment Nationwide View Details β†’

Upon installation of BD Kiestra" InoqulA+" and BeA version 5.1 and 5.1.1 as part of the Icefall A platform, plate information was not visible in Synapsys" after processing has occurred. This could possibly lead to a delayed diagnosis and/or treatment or need for specimen recollection streaking plated media, and inoculating tubes and slides. In Semi-Automated (SA) mode, plates are automatically selected, barcoded, streaked in a pre-configured pattern while the user manually inoculates plates, tubes, and slides. An optional biosafety cabinet on the SA module provides personnel, product, and environmental protection. The InoqulA+" solution is indicated for use in the clinical laboratory.

Mar 22, 2023 Diagnostic Equipment Nationwide View Details β†’

Church & Dwight First Response Pregnancy Kits was marketed with the Easy Read App without a new 510k. There is also a potential for Easy Read App to be unable to reads the test results (i.e., no results reported on the APP screen) or to misread the analog results shown on the pregnancy test stick and may lead to misinterpretation of false positive or false negative tests by the user.

Jan 25, 2023 Diagnostic Equipment Nationwide View Details β†’

There is a potential that the distal end of the catheter may be bent beyond its intended curvature and when connected to patient monitoring device, the monitor may display an error message.

Feb 14, 2023 Diagnostic Equipment Nationwide View Details β†’