When a prior study is being replaced in the workflow step, in certain scenarios (based on the Display Protocol configuration) the prior study will only be replaced in the active Workflow Step and not show in all other workflow steps. The other workflow steps will continue to show the initially loaded study.

Aug 23, 2017 Diagnostic Equipment Nationwide View Details β†’

During collimator exchange, the alignment of the collimator cart and detectors may cause a collimator exchange fail, and a collimator may drop to the floor beside the collimator cart. The collimator may be partially supported by the cart (e.g. leaning against the cart), or it may fall/slide all the way to the floor.

Dec 15, 2017 Diagnostic Equipment Nationwide View Details β†’

During collimator exchange, the alignment of the collimator cart and detectors may cause a collimator exchange fail, and a collimator may drop to the floor beside the collimator cart. The collimator may be partially supported by the cart (e.g. leaning against the cart), or it may fall/slide all the way to the floor.

Dec 15, 2017 Diagnostic Equipment Nationwide View Details β†’

During collimator exchange, the alignment of the collimator cart and detectors may cause a collimator exchange fail, and a collimator may drop to the floor beside the collimator cart. The collimator may be partially supported by the cart (e.g. leaning against the cart), or it may fall/slide all the way to the floor.

Dec 15, 2017 Diagnostic Equipment Nationwide View Details β†’

During collimator exchange, the alignment of the collimator cart and detectors may cause a collimator exchange fail, and a collimator may drop to the floor beside the collimator cart. The collimator may be partially supported by the cart (e.g. leaning against the cart), or it may fall/slide all the way to the floor.

Dec 15, 2017 Diagnostic Equipment Nationwide View Details β†’

The low and high controls for the product are returning results above the assigned values.

Jan 4, 2018 Diagnostic Equipment View Details β†’

During collimator exchange, the alignment of the collimator cart and detectors may cause a collimator exchange fail, and a collimator may drop to the floor beside the collimator cart. The collimator may be partially supported by the cart (e.g. leaning against the cart), or it may fall/slide all the way to the floor.

Dec 15, 2017 Diagnostic Equipment Nationwide View Details β†’

Spacelabs has received multiple complaints reporting telemetry beds dropping off the Spacelabs Central Station resulting in a loss of monitoring.

Jan 17, 2018 Diagnostic Equipment View Details β†’

Software update to correct several issues that include (1)Potential data loss, (2) Study mix-up, (3) Incorrect measurements on multi-frame images, (4) Dearchiving issue, and (5) Unauthorized access of data due to inadequate permissions for shared folders.

Aug 18, 2017 Diagnostic Equipment Nationwide View Details β†’

Hemosphere System with the following three components: HEM1 Advanced Monitor, HEMSGM10 (Swan-Ganz Module), and HEMOXSC100 (Oximetry Smart Cable). Product Usage: The HemoSphere Advanced Monitor (HEM1) is intended to be used in combination with a compatible Edwards hemodynamic monitoring technology module and/or cable and accompanying Edwards accessories and/or disposables. It provides Edwards hemodynamic monitoring technologies through modular connections. The HemoSphere Swan-Ganz Module (HEMSGM10) is intended to be used by qualified personnel or trained clinicians in a critical care environment in a hospital setting. It is a multi-use device that works in conjunction with the HemoSphere Advanced Monitor, patient CCO cable and compatible Swan-Ganz catheter to acquire and process temperature data supporting intermittent cardiac output (iCO), continuous cardiac output (CCO) and right ventricular end diastolic volume (EDV) monitoring. The HemoSphere Oximetry Smart Cable (HEMOXSC100) is intended to be used by qualified personnel or trained clinicians in a critical care environment in a hospital setting. It is a multi-use device that connects with a compatible Edwards monitor on one end and any approved Edwards oximetry catheter on the other end to continuously measure venous oxygen saturation by reflectance spectrophotometry. LEDs within the oximetry cable transmit light fiber optically to the distal end of the catheter. The amount of light absorbed, refracted, and reflected depends on the relative amounts of oxygenated and deoxygenated hemoglobin in the blood. This optical intensity data is gathered by the oximetry catheter, processed by the HemoSphere Oximetry Cable, and displayed on a compatible monitoring platform. Parameter output is mixed venous oxygen saturation (SvO2) or central venous oxygen saturation (ScvO2).

Edwards Lifesciences

Class I - Dangerous

Pre-procedural issues related to software defects

Oct 2, 2017 Diagnostic Equipment Nationwide View Details β†’

Buchanan Heat Pluggers will possibly overheat while used with the Elements Obturation Unit (EOU).

Dec 27, 2017 Diagnostic Equipment Nationwide View Details β†’

The possibility exists that use of the Uros Automated Urine Output and Temperature Monitor may lead to the loss of urine output measurement data and/or urine output measurement inaccuracies resulting in an impact on clinical treatment decisions.

Sep 29, 2017 Diagnostic Equipment View Details β†’

The recalled lots have demonstrated unexpected false positive THC results.

Nov 14, 2017 Diagnostic Equipment Nationwide View Details β†’

CARESCAPE Central Station (CSCS) software version 2.0.2 units may experience unexpected NO COMM (No Communication) and network communication issues after boot-up or system restart.

Jan 11, 2018 Diagnostic Equipment Nationwide View Details β†’

This recall has been initiated due to a potential malfunction of the photo interrupter (Pl). The potential malfunction has been attributed to aging and premature deterioration of the Pl collector current.

Jun 11, 2017 Diagnostic Equipment Nationwide View Details β†’

The reusable temperature probes are provided with instructions for sterilization that have not been proven through a validation study.

Mar 13, 2017 Diagnostic Equipment Nationwide View Details β†’

Siemens is releasing a letter to inform about potential data loss relevant to diagnosis.

Jul 25, 2017 Diagnostic Equipment Nationwide View Details β†’