Roche Diagnostics

39 recalls • • Categories: Other Medical Devices, Diagnostic Equipment, Infusion Pumps

Using the following versions of cobas infinity software (2.0 thorough 2.5), there is a potential where the results from the first sample subsequent to the bottle change, (when using the Standby bottle function), does not display a quality control (QC) alarm when one should be present. If the QC is out of range on the stand-by bottle and it is not removed from the system, there is a potential that when the status of the Standby bottle changes from the Standby bottle to the Current bottle status, QC alarms will not be displayed next to the sample result.

Feb 4, 2019 Other Medical Devices View Details →

The firm has confirmed complaints regarding signal drops on the cobas e 801 module after a ProCell II M bottle changeover, which may lead to incorrect medical decisions with respect to diagnostics and patient treatment.

Mar 15, 2019 Other Medical Devices Nationwide View Details →

New endogenous interference claims have been established for the following assays used on the cobas c 311 analyzer and the cobas c 501, 502, 701, 702, and Modular Analytics P/D modules which may have potential medical risk. ***Update: Cobas c111 and COBAS INTEGRA 400 plus analyzers are also impacted for BILT3 and LACT2 assays***

Dec 17, 2018 Diagnostic Equipment Nationwide View Details →

New endogenous interference claims have been established for the following assays used on the cobas c 311 analyzer and the cobas c 501, 502, 701, 702, and Modular Analytics P/D modules which may have potential medical risk. ***Update: Cobas c111 and COBAS INTEGRA 400 plus analyzers are also impacted for BILT3 and LACT2 assays***

Dec 17, 2018 Diagnostic Equipment Nationwide View Details →

New endogenous interference claims have been established for the following assays used on the cobas c 311 analyzer and the cobas c 501, 502, 701, 702, and Modular Analytics P/D modules which may have potential medical risk. ***Update: Cobas c111 and COBAS INTEGRA 400 plus analyzers are also impacted for BILT3 and LACT2 assays***

Dec 17, 2018 Infusion Pumps Nationwide View Details →

COBAS INTEGRAÂż 400 plus and cobas c 111 analyzers Additional Extra Wash Cycle Configurations and/or Batch Mode Needed for Specific Tests Due to Carry-over

Dec 14, 2018 Diagnostic Equipment Nationwide View Details →

COBAS INTEGRAÂż 400 plus and cobas c 111 analyzers Additional Extra Wash Cycle Configurations and/or Batch Mode Needed for Specific Tests Due to Carry-over

Dec 14, 2018 Diagnostic Equipment Nationwide View Details →

Potential for erroneous result messages for the Anti-HAV IgM assay when run on the cobas e 602 module. Discrepant result reporting may result.

Dec 17, 2018 Diagnostic Equipment Nationwide View Details →

Limits of Detection (LoD) for protein, nitrite, leukocytes, and erythrocytes on the Urisys 1100 urine analyzer with Chemstrip 5 OB, Chemstrip 7, Chemstrip 10 MD, and Chemstrip 10 UA test strips were higher than what is listed in the test strip method sheets may lead to false negative results for the affected parameters

Sep 24, 2018 Diagnostic Equipment Nationwide View Details →

Sample material may potentially come in contact with the pipetting nozzle during operation of cobas p 612 pre-analytical system (63x) (LCP1) with non-filter tips. The possible presence of biological material on the nozzle may cause contamination resulting in potential false positive results, depending on the sensitivity of the analytical technology.

Jul 16, 2018 Diagnostic Equipment View Details →

The device may give a falsely elevated result that is non-reproducible. If vitamin D level is monitored by laboratory tests and adapted based on the result, a dosage reduction of vitamin D supplementation cannot be excluded, and as a consequence, vitamin D deficiency may develop over time.

Apr 27, 2018 Diagnostic Equipment Nationwide View Details →

The device may give a falsely elevated result that is non-reproducible. If vitamin D level is monitored by laboratory tests and adapted based on the result, a dosage reduction of vitamin D supplementation cannot be excluded, and as a consequence, vitamin D deficiency may develop over time.

Apr 27, 2018 Diagnostic Equipment Nationwide View Details →

The syringe plunger on the device may be mounted in a tilted position, which applies mechanical stress to the plunger. In the worst case scenario, the plunger may crack leading to impaired syringe function.

Apr 3, 2018 Other Medical Devices View Details →

The software responsible for starting scheduled AutoQC measurements (scheduler) will not activate.

Feb 22, 2018 Diagnostic Equipment Nationwide View Details →

The software responsible for starting scheduled AutoQC measurements (scheduler) will not activate.

Feb 22, 2018 Diagnostic Equipment Nationwide View Details →

The software responsible for starting scheduled AutoQC measurements (scheduler) will not activate.

Feb 22, 2018 Diagnostic Equipment Nationwide View Details →

The software responsible for starting scheduled AutoQC measurements (scheduler) will not activate.

Feb 22, 2018 Diagnostic Equipment Nationwide View Details →

The previous version of method sheets for the Acetaminophen assay on the COBAS INTEGRA 400 plus/800/800 CTS analyzers and the MODULAR ANALYTICS P module are missing the following statement in the Limitations-interference section: "In very rare cases, gammopathy, in particular type IgM (WaldenstrÂżm s macroglobulinemia), may cause unreliable results."

Jan 2, 2018 Diagnostic Equipment Nationwide View Details →

A warning is being added to the cobasÂż 6000 MODULAR Series System - c501 and the cobasÂż 8000 MODULAR Analyzer Series - c502 Operator Manuals to prevent operator injury during maintenance.

Jul 18, 2017 Other Medical Devices Nationwide View Details →

A software malfunction can occur on the cobas e 411 and Elecsys 2010 analyzers in the Sample& Control data file which may lead to a potential data mismatch.

Jul 5, 2017 Infusion Pumps Nationwide View Details →

A software malfunction can occur on the cobas e 411 and Elecsys 2010 analyzers in the Sample& Control data file which may lead to a potential data mismatch.

Jul 5, 2017 Infusion Pumps Nationwide View Details →

Brand Name: Âż cobas c 6000 MODULAR Series System e 601 Âż cobas c 8000 MODULAR Series System - e 602 Âż Roche / Hitachi MODULAR Analytics Combination System Model/Catalog/Part Number: MODULAR Analytics E 170 Âż 03022109001 Âż 03023109973 Âż 03739040001 Âż 03739040692 Âż 05023572001 Âż 05023599001 cobas e 601 module Âż 04745922001 Âż 04745922692 Âż 05036348001 Âż 05036348692 Âż 05860652001 cobas e 602 module Âż 05990378001 The Roche/Hitachi MODULAR Analytics System (E170) is a fully automated, random-access, software- controlled system for immunoassay and photometric analysis intended for qualitative and quantitative in vitro determinations using a wide variety of tests. The cobas 6000 series (e 601) is a fully automated, random-access, software-controlled system for immunoassay and photometric analysis intended for qualitative and quantitative in vitro determinations using a wide variety of tests. It is optimized for high throughput workloads in the professional environment using a combination of Ion selective electrodes (ISE), a photometric analysis unit an immunoassay analysis module. The cobas 8000 Modular Analyze Series (e602) is a fully automated system for Clinical chemistry analysis, intended for the in vitro qualitative and quantitative determination of analytes in body fluids. It is optimized for high throughput workloads in the professional environment using a combination of ion selective electrodes (ISE) and a photometric analysis unit.

Class I - Dangerous

Roche has confirmed that a possible sample mismatch issue may occur on the MODULAR ANALYTICS E 170 module, cobas e 601 analyzer, or cobas e 602 analyzer due to a software limitation.

Jun 29, 2017 Diagnostic Equipment Nationwide View Details →

a gap between the conveyor belt and the rack tray table (plastic part) may cause vibration of the 5 position racks during the transport. This issue can pose a potential risk to involved operators and can also lead to potential cross contamination of samples in the affected racks.

May 9, 2017 Diagnostic Equipment View Details →
Class I - Dangerous

e-barcode and value sheet for PreciControl Varia contains a typographical error for the target values for the Elecsys PTH (parathyroid hormone) and Elecsys PTH STAT immunoassays

Apr 10, 2017 Other Medical Devices Nationwide View Details →

Due to a design change in 2015, corrosion on the sample probe electrical contacts can occur and lead to a disturbance of the sample liquid level detection (LLD). When disturbance of the sample liquid level detection (LLD) occurs, the affected sample probe may dip into the sample material deeper than intended. This may lead to carryover and medical risk cannot be excluded.

Mar 21, 2017 Diagnostic Equipment Nationwide View Details →

"Roche Diagnostics Corp. initiated a voluntary correction because a rack crash may occur on the Cobas 8100 bi-directional reformatter (BRF) and uni-directional reformatter (URF) modules with software version 02-xx, only when rack buffering is activated and the rack buffer is completely full. This issue can lead to sample spillage, posing a potential risk to operators / laboratory staff due to exposure to potentially infectious material, cross-contamination of samples in the affected racks and erroneous results due to sample carry-over."

Mar 1, 2017 Other Medical Devices View Details →

Roche Diagnostics Corp. initiated a voluntary correction because a rack crash may occur on the Cobas 8100 bi-directional reformatter (BRF) and uni-directional reformatter (BRF) modules with software version 02-xx, only when rack buffering is activated and the rack buffer is completely full. This issue can lead to sample spillage, posing a potential risk to operators / laboratory staff due to exposure to potentially infectious material, cross-contamination of samples in the affected racks and erroneous results due to sample carry-over.

Mar 1, 2017 Other Medical Devices View Details →