Qiagen Sciences

23 recalls β€’ β€’ Categories: Other Medical Devices, Diagnostic Equipment, Infusion Pumps, Surgical Instruments

Heater shaker module does not perform heating if the temperature is set below 40ΒΏC for static incubation steps when running IVD protocol QIAampΒΏ DSP DNA Mini Kit (cat. no. 61304), Protocol: Isolation of genomic DNA from Gram-positive bacteria (Script filename: Kt_name_Bacteria (Gram+) or rY'east_Enzymatic Lysis_ V2) which could potentially cause delayed or erroneous results depending on the downstream assay.

Jun 3, 2024 Diagnostic Equipment Nationwide View Details β†’

During the "Load tip racks and enzymes" step of the run set-up, the info screen indicates "minimal volume to be loaded", but the indicated volume is instead the exact volume that should be loaded. Misunderstanding the guidance may lead to over diluted, under diluted, or improperly lysed sample, which in turn could lead to false negative or false positive results.

Nov 21, 2021 Other Medical Devices Nationwide View Details β†’

Increased occurrence rate of false positive results, lead to a false positive sample result that could subsequently be incorrectly reported from the laboratory. A false positive result could lead to the risk of the patient being exposed to an inappropriate or suboptimal anti-cancer treatment and/or unnecessarily experiencing side effects

Jul 20, 2022 Infusion Pumps View Details β†’

Increased occurrence rate of false positive results, lead to a false positive sample result that could subsequently be incorrectly reported from the laboratory. A false positive result could lead to the risk of the patient being exposed to an inappropriate or suboptimal anti-cancer treatment and/or unnecessarily experiencing side effects

Jul 20, 2022 Infusion Pumps View Details β†’

Increased occurrence rate of false positive results, lead to a false positive sample result that could subsequently be incorrectly reported from the laboratory. A false positive result could lead to the risk of the patient being exposed to an inappropriate or suboptimal anti-cancer treatment and/or unnecessarily experiencing side effects

Jul 20, 2022 Infusion Pumps View Details β†’

There is an increased rate of potential false positive results for the Influenza A (no subtype) target, which may lead to 1) inappropriate antiviral use, 2) erroneous or delayed differential diagnosis and missing of an alternative diagnosis.

Jul 15, 2020 Infusion Pumps Nationwide View Details β†’

When using the Rotor-Gene Q with Software version 2.3.4 completing a LIMs export, the .csv file reports the calculated concentration result value as a logarithmic value, and could lead to a false negative result, which could lead to serious medical consequences such as the suspension or non-initiation of treatment

Jan 28, 2020 Other Medical Devices Nationwide View Details β†’

QIAsymphony software version 5.0.3 - Software issue incorreclty assigns the 2D bar code eluate ID to the sample within the results file. If 2D bar code eluate IDs are not checked against the sample ID prior to downstream application the incorrect tube may be selected and it could have the potential to lead to delayed results or incorrect patient reporting

Jul 2, 2019 Surgical Instruments Nationwide View Details β†’

The deparaffinization solution contains a contaminant, which leads to reduced lysis efficiency of the affected lot, resulting in significantly reduced yields and less sensitive downstream applications.

May 6, 2019 Diagnostic Equipment Nationwide View Details β†’

An issue with the power branching printed circuit board (PCB) on the instrument that has the potential to trigger a heater malfunction was discovered. If this failure were to occur, nucleic acid extractions could be compromised and extractions need to be repeated. This could cause a delay in obtaining results from downstream applications.

Jul 23, 2018 Surgical Instruments Nationwide View Details β†’